Advertisement

Neutral Tap Kits
Copyright © Briggs & Stratton
Milwaukee, WI, USA.
Installation Instructions
For Direct Power
Help is just a moment away!
Call: Technical Services 800-743-4115
Monday-Friday 8:00 AM to 5:00 PM Central Time
Model 6344
Model 6345
Model 6346
Questions?
80015784
Revision ( A )

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6344 and is the answer not in the manual?

Questions and answers

Summary of Contents for Briggs & Stratton 6344

  • Page 1 Installation Instructions Neutral Tap Kits For Direct Power Model 6344 Model 6345 Model 6346 Questions? Help is just a moment away! Call: Technical Services 800-743-4115 Monday-Friday 8:00 AM to 5:00 PM Central Time 80015784 Copyright © Briggs & Stratton Revision ( A )
  • Page 2 Neutral Tap Kit Contents 6346 Neutral Tap Kit Contents: 6344 Neutral Tap Kit Contents: • Parallel Tap GTA 250-0 (1 ea) • Parallel Tap GTA 2-2 (1 ea) • Cover GTC- 250-350 (1 ea) • Cover GTC – 2 (1 ea) •...
  • Page 3 Safety SAVE THESE INSTRUCTIONS - This installation sheet WARNING Generator produces hazardous voltage. contains important safety instructions that should be followed Failure to properly ground generator could result during installation of the equipment. in electrocution. Failure to isolate generator from utility power could result in death or serious injury Safety Alert Symbol and Signal Words to electric utility workers, due to back-feed of electrical The safety alert symbol...
  • Page 4 Install Neutral Tap Kit Thank you for purchasing this home standby accessory. When installed according to these instructions, the Check to make sure that all power sources to the meter monitoring device will provide years of dependable service. enclosure are OFF. Keep your purchase receipt with this instruction sheet and store with your other generator manuals after installation.
  • Page 5 Tighten the screw on the Neutral tap to the Reconnect the Neutral wire to the Neutral terminal recommended torque value listed in Tables 1 and 2. inside the meter enclosure. Use Torque values per manufacturer’s recommendation. Install the insulating Connect the 2 AWG White Neutral wire to the Neutral cover over the Neutral tap as shown in Figures 3 and 4.
  • Page 6 When installing the meter adapter to the meter socket, check to make sure that jaws align properly with the protective cover as shown in Figure 5. Figure 5 10. This concludes the installation of the Neutral Tap kit. BRIGGSandSTRATTON.COM...
  • Page 7 This page intentionally left blank...
  • Page 8 This page intentionally left blank BRIGGSandSTRATTON.COM...

This manual is also suitable for:

63456346