Briggs & Stratton Elite 030209-1 Operator's Manual

Briggs & Stratton Elite 030209-1 Operator's Manual

5500w elite series
Table of Contents

Advertisement

Available languages

Available languages

Operator's Manual
Manual del Operario
030209-1
(5500W)
WARNING
ADVERTENCIA
Before using this product, read this
Antes de utilizar el producto, lea este
manual and follow all Safety Rules
manual y siga todas las Reglas de Seguridad
and Operating Instructions.
e Instrucciones de Uso.
Questions? Help is just a moment away!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline - 1-800-743-4115 M-F 8-5 CT
Llamada: Generador Helpline - 1-800-743-4115 M-F 8-5 CT
web: www.briggsandstratton.com
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
Manual No. 197269GS
JEFFERSON,WISCONSIN, U.S.A.
Revision 1 (11/09/2005)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Briggs & Stratton Elite 030209-1

  • Page 1 Operator’s Manual Manual del Operario 030209-1 (5500W) WARNING ADVERTENCIA Before using this product, read this Antes de utilizar el producto, lea este manual and follow all Safety Rules manual y siga todas las Reglas de Seguridad and Operating Instructions. e Instrucciones de Uso. Questions? Help is just a moment away! Preguntas? La ayuda es justa un momento lejos! Call: Generator Helpline - 1-800-743-4115 M-F 8-5 CT...
  • Page 2: Table Of Contents

    Briggs & Stratton Power Products Group, LLC. 5500W Portable Generator SAFETY RULES This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
  • Page 3 • NEVER start or stop engine with electrical devices plugged in and turned on. 5500W Portable Generator Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
  • Page 4 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws. 5500W Portable Generator CAUTION Excessively high operating speeds increase risk of injury and damage to generator.
  • Page 5: Know Your Generator

    Choke Lever — Used when starting a cold engine. Circuit Breakers (AC) — Push to reset circuit breakers are provided to protect the generator against electrical overload. 5500W Portable Generator Fuel Tank Data Tag — Provides model, revision and serial number of generator.
  • Page 6: Assembly

    • Engine oil • Operator’s manual Figure 1 — Install Wheel Kit Capscrew Handle Mounting Leg 5500W Portable Generator • Engine operator’s manual • Wheel kit If any parts are missing or damaged, call the generator helpline at 1-800-743-4115. Install Wheel Kit The wheel kit is designed to greatly improve the portability of your generator.
  • Page 7: Assembly

    NOTE: The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing. 5500W Portable Generator Add Fuel NOTE: This gasoline engine is certified to operate on gasoline. Exhaust Emission Control System: EM (Engine Modifications).
  • Page 8: Using The Generator

    • DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet. • DO NOT allow unqualified persons or children to operate or service generator. 5500W Portable Generator Generator Location Generator Clearance WARNING Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.
  • Page 9: Operation

    This unit may be equipped with a low oil protection device. See engine operator’s manual. 5500W Portable Generator Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).
  • Page 10: Stopping The Engine

    240V 120V Y (Hot) NEMA L14-30 5500W Portable Generator This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 5,500 watts of power (5.5 kW) at 22.9 Amps for 240 Volts or two independent 120 Volt loads at 20 Amps each.The outlet is protected by...
  • Page 11: Power Management

    Permit the generator output to stabilize (engine runs smoothly and attached device operates properly. 5500W Portable Generator Plug in and turn on the next load. Again, permit the generator to stabilize. Repeat steps 4 and 5 for each additional load.
  • Page 12: Specifications

    KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS. 5500W Portable Generator Generator Maintenance Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors.
  • Page 13: Storage

    • DO NOT place a storage cover over a hot generator. • Let equipment cool for a sufficient time before placing the cover on the equipment. 5500W Portable Generator Engine Storage See engine operator’s manual for instructions. Other Storage Tips •...
  • Page 14: Troubleshooting

    "bogs" down" when loads are connected. Generator will not start; or starts and runs rough. Generator shuts down during operation. Generator lacks power. 5500W Portable Generator Cause One of the circuit breakers is open. Fault in generator. Poor connection or defective cord set.
  • Page 15: Warranty

    The engine and starting batteries are warranted solely by the manufacturers of those products. 2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and Home Standby Generator System - Less than 10 KW, outside of European Union.
  • Page 16: Reglas De Seguridad

    CONSERVE ESTAS INSTRUCCIONES TABLA DE CONTENIDOS Reglas De Seguridad ....... . 16-18 Conozca Su Generador .
  • Page 17 ADVERTENCIA Al generador funcionar, se produce monóxido de carbono, un gas inodoro y venenoso. El respirar el monóxido de carbono, producirá náusea, desmayo o la muerte. • Opere el generador SOLAMENTE al aire libre. • Asegúrese de que los gases de escape no puedan entrar por ventanas, puertas, tomas de aire de ventilación u otras aberturas en un espacio cerrado en el que puedan acumularse.
  • Page 18 ADVERTENCIA Chispear involuntario puede tener como resultado el fuego o el golpe eléctrico. CUANDO AJUSTE O HAGA REPARACIONES A SU GENERADOR • Siempre desconecte el alambre de la bujía y colóquelo donde no pueda entrar en contacto con la bujía. CUANDO PRUEBE LA BUJÍA DEL MOTOR •...
  • Page 19: Conozca Su Generador

    CONOZCA SU GENERADOR Lea este Manual del Operario y las reglas de seguridad antes de operar su generador. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras. Tapa del Depósito del Aceite Tomacorrientes Dobles de...
  • Page 20: Montaje

    MONTAJE Su generador requiere de ciertos procedimientos de montaje y solo estará listo para ser utilizado después de haberle suministrado servicio con el combustible y aceite recomendados. Si usted tiene problemas con el montaje de su generador, por favor llame a la línea de ayuda para generadores al 1-800-743-4115.
  • Page 21: Agregue Combustible

    Introduzca una arandela por el eje y coloque una anilla en “e” en la ranura del eje. Para ello, apriete con unos alicates desde la parte superior de la anilla en “e” hacia la parte inferior del eje. PRECAUCIÓN Las anillas en “e” pueden provocar lesiones oculares. Las anillas en “e”...
  • Page 22: Operación

    USO DEL GENERADOR Tierra del Sistema El generador dispone de una conexión a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema está conectada al cable de CA neutro que, a su vez, está conectado al bastidor del generador (vea “Descripión del Equipo”).
  • Page 23: Encienda El Motor

    OPERANDO EL GENERADOR Encienda el Motor Desconecte todas las cargas eléctricas del generador. Use las siguientes instrucciones para encender: Asegúrese de que la unidad está en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en una superficie plana, se pueden producir problemas de arranque y de parada durante el funcionamiento.
  • Page 24: Parado Del Motor

    Parado Del Motor Gire lejos y desconecte todas las cargas eléctricas de los tomaco-rrientes del panel del generador. NUNCA de arranque o detenga el motor con todos los dispositivos eléctricos conectados y encendidos. Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador.
  • Page 25 NO SOBRECARGUE GENERADOR Capacidad Usted debe asegurarse que su generador puede proveer el suficiente vataje calificado (cuando esté funcionando) y de carga (al encender) para los aparatos a los cuales va a proveer la energía, al mismo tiempo. Siga estos pasos: Seleccione los aparatos que recibirán la energía, al mismo tiempo.
  • Page 26: Mantenimiento

    ESPECIFICACIONES Vataje que empieza ....8,500 Vatios (8.5 kW) Vataje ......5,500 Vatios (5.5 kW) Corriente valorada de Carga de C.A.: a 240 Voltios .
  • Page 27: Almacenamiento

    ALMACENAMIENTO El generador deberá ser encendido al menos una vez cada siete días y deberá dejarlo funcionar al menos durante 30 minutos. Si no puede hacer esto y debe almacenar la unidad por más de 30 días, siga las siguientes instrucciones para preparar su unidad para almacenamiento.
  • Page 28: Garantia

    POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE EQUIPOS BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC Fecha de entrada en vigor: 1 de Septiembre de 2004. Sustituye a todas las garantías sin fecha y a las de fecha anterior al 1 de Septiembre de 2004 Briggs &...

Table of Contents