    SAVE THESE iNSTRUCTiONS TABLE OF CONTENTS SAFETY RULES Safety Rules ........Know Your Generator ......This is the safety alert symbol, it is used alert you to potential personal injury hazards. Assembly ........Obey all safety messages that follow this Operation ........
  • Page 3 |WARNING Using a generator indoors WILL KILL YOU IN MINUTES. Exhaust contains carbon monoxide, WHEN ADDING OR DRAINING FUEL poison gas you cannot see or smell. Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure tank.
  • Page 4 WARNING DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed . When starting engine, pull cord slowly until resistance is felt speed. and then pull rapidly to avoid kickback. DO NOT modify generator in any way.
  • Page 5 KNOWYOUR GENERATOR Read this Operator's Manual and safety rules before operating your generator° Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. may vary Alternator slightly in appearance Fuel Tank from that shown here...
  • Page 6 ASSEMBLY • 30Amp extension cord • Wheel Your generator requires some assembly and is ready for Install Wheel use after it has been properly serviced with the recommended oil and fuel. NOTE: Wheel kit is not intended for over=the-road use. You will need the following tools to install these If you have any problems with the assembly of your...
  • Page 7: Add Engine Oil

    6. Repeat Add Fuel step 4 and 5 to secure second wheel. Tip generator so that engine side is down. NOTE: This gasoline engine is certified to operate gasoline. Exhaust Emission Control System: EM (Engine Line up holes in support leg with holes in generator frame.
  • Page 8: Generator Location

    USING THE GENERATOR Generator Location Generator Clearance System Ground WARNING The generator has a system ground that connects generator frame components to the ground terminals the AC output receptacles.The system ground is connected Keep at least 5 ft. (152 cm) clearance on all sides of generator to the AC neutral wire (see "Equipment Description",...
  • Page 9: Electrical Loads

    OPERATING WARNING GENERATOR Startin ine Disconnect all electrical loads from the generator. Use the following start instructions: Make sure unit is on a level surface. DO NOT touch hot surfaces and avoid hot exhaust gases. IMPORTANT: Failure to start and operate unit on a level Allow equipment to cool before touching.
  • Page 10 1201240 Volt AC, 30 Amp, Locking Sto_g_ Engine Receptacle Turn OFF and unplug all electrical loads from generator panel receptacles. NEVER start or stop engine Use a NEMA LI4-30 plug with this receptacle. Connect with electrical devices plugged in and turned 4-wire cord set rated for 250VoItAC loads at 30Amps...
  • Page 11: Power Management

    DON'T OVERLOAD Plug in and turn on the next load. Again, permit the generator to stabilize. GENERATOR Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, acity as described above.
  • Page 12: Specifications

    SPECiFiCATiONS Maintenance Generator Generator maintenance consists of keeping the unit clean Starting Wattage ....... 7,800 watts and dry. Operate and store the unit in a clean dry Wattage ......5,500 watts environment where it will not be exposed to excessive AC Load Current: dust, dirt, moisture or any corrosive...
  • Page 13: Engine Storage

    STORAGE Engine Storage See engine operator's manual for instructions. The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot Other Tips Storage be clone and you must store the unit for more than •...
  • Page 14: Troubleshooting

    TROUBLESHOOTING Problem Correction Cause One of the circuit breakers is Reset circuit breaker. open. Fault in generator. Contact Authorized service facility. No AC output is available, Poor connection or defective cord Check and repair. generator is running. set. Connected device is bad. Connect another device that is in...
  • Page 15 Effective February 1,2006 replaces all undated Warranties and all Warranties dated before February 1,2006 LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both.
  • Page 16: Reglas De Seguridad

    CONSERVE ESTAS INSTRUCCIONES TABLA DE CONTENIDOS REGLAS DE SEGURIDAD Reglas De Seguriclacl ........ 16-18 Conozca Su Generador ........ para advertir _ste es el simboio al usuario de alerta de un posible de seguridad. riesgo Sirve para Plontaje .......... 20-2 I su integridad fisica.
  • Page 17 ADVERTENC El usar un generador en espacios interiores [e causar_ Ta muerte en unos minutos. Los gases de combustidn contienen mondxido de carbono, un gas venenoso que usted no CUAMDOANADA COMBUSTIBLE OVACJE EL puede ver ni oler. DEPOSITO Apague el generador (posici6n OFF) y d&jelo enfriar al menos por...
  • Page 18 ADVERTENClA NO cambie ninguna velocidad determinada. El generador suministra una frecuencia y un vokaje calificado cuando funciona a una ve[ocidad determinada. Cuando arranque el motor, tire [entamente cable hasta sendr resistencia y, a condnuaci6n, tire r_pidamente de &[ para evitar NO modifique al generador en ninguna forma.
  • Page 19 CONOZCA SU GENERADOR Lea este Manual del Operario y las reglas de seguridad antes de operar su generador. Compare las ilustraciones con su Generador para farniliarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 20 HONTAJE Cuerda de la extensi6n del 30 Amperio Juego de ruedas Su generador requiere de ciertos procedimientos de montaje solo estar_ listo para ser utilizado despu6s de haberle Instale el Juego de Ruedas suministrado servicio con el combustible y aceite recomendados.
  • Page 21 6. Repita lospasos del 4 y5para a segurar lasegunda rueda. Agregue Combustible 7. Dele lavuelta a lgenerador deforma q ue ellado del m otor NOTA: Este motor est_ cerdficado para funcionar con gasolina. quede abajo. Sistema de control de emisiones de gases de escape: EM 8.
  • Page 22: Uso Del Generador

    DEL GENERADOR Ubicaci6n del Generador Espacio LibreAIrededor del Generador Tierra del Sistema ADVERTENClA El generador dispone de una conexi6n a tierra del sistema que conecta los componentes del basddor a los terminales de derra de los enchufes hembra de salida de CA. La derra del sistema est_ conectada al cable de CA neutro que, a su vez, est_ Deje un espacio minimo de 152 cm (5 pies) alrededor del generador,...
  • Page 23 OPERANDO EL GENERADOR ADVERTENClA Encienda el Hotor Desconecte todas las cargas el_ctricas del generador. Use las siguientes instrucciones para encender: AsegQrese de que ia unidad est_ en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en una superficie plana, se pueden proclucir problemas...
  • Page 24 Parado Del Motor 1201240 Yoltios 30 Amp, Recept_culo de Seguridad Desconecte todas las cargas el_ctricas de los tomaco- rrientes del panel del generador. NUNCA de arranque o Use un tap6n NEMA L I4-30 con este recept_culo. Conecte detenga el motor con todos los disposidvos el6ctricos...
  • Page 25 SOBRECARGUE GENERADOR Conecte y encienda la pr6xima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos 4 y 5 para cada carga adicional que usted tenga. Usted debe asegurarse que su generador puede proveer suficiente vataje calificado (cuando est6 funcionando) y de carga NUNCA afada...
  • Page 26: Especificaciones

    ESPECIFICACIONES NOTA: NO recomendamos el uso de mangueras de jardin para limpiar el generador. El agua podria introducirse en el sistema Vataje que empieza ....7,800Vatios (7.8 kW) combustible del motor y causar problemas.Adem_s, si el agua se Vataje ......5,500Vatios (5.5 kW) introduce...
  • Page 27 ALHACENAHIENTO Aimacenando el Hotor Consulte el manual del operario del motor para las instrucciones El generador deber_ ser encendido al menos una vez cada siete de c6mo preparar adecuadamente el motor para su dias y deber_ dejarlo funcionar al menos durante 30 minutos.
  • Page 28 Fecha de entrada en vigor:l de Febrero de 2006. Sustituye a todas las garantias sin fecha y a las de fecha anterior al 1 Febrero de 2006 GARANTiA LIMITADA Briggs & Stratton Power Products Group, LLC reparara o sustituira sin cargo alguno cualquier componente...

This manual is also suitable for:

Powerboss 030255Powerboss 030255

Table of Contents