Use Instructions; Main Functions; Technical Parameters - La Sommeliere CTVNE142A Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

III – USE INSTRUCTIONS
If the ambient temperature is above or below the recommended ambient temperature range, the performance of the unit may be
affected. For example, placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate.
Note:
When you use the Wine Cooler for the first time or restart the Wine Cooler after having been shut off for a long time,
there could be a few degrees variance between the temperature you select and the one indicated on the LED readout.
This is normal and it is due to the length of the activation time. Once the Wine Cooler is running for a few hours
everything will be back to normal.
If the unit is unplugged, power lost, or turned off, you must wait 3 to 5 minutes before restarting the unit. If you attempt
to restart before this time delay, the Wine Cooler will not start.

Main functions

Display temperature and humidity; Control temperature automatically; Control lighting;
Alarm when temperature exceeds temperature limit, degrees Fahrenheit and Celsius transformation

Technical parameters

Measure range: -45℃ ~ +99℃(-45F-210F); Resolution: 0.1℃; Relative humidity: 0-99%RH; Humidity accuracy: ±5%RH;
Temperature accuracy: ±1℃ (-40℃~50℃) ; ±2℃ (50℃~70℃) ; Temperature controlling range: 5℃~20℃;
Power supply: 220-240VAC、50/60Hz; Relay contact capacity: Cool 10A/240VAC; Heat 5A/240VAC; Fan 12Vdc/80mA; Lighting
12Vdc/120mA
Operation and panel diagram
1.
On / Off: press and hold on/off key
set temperature value. After delay, the cold system starts to work.
2.
Lighting: permanent light: Press lighting key
on, press the lighting key again, the light is off icon is disappearing from the screen.
3.
Adjust the controlling temperature (users set): press
upward key or downward key
button again to confirm or not press any button in 5 seconds, the number of temperature will be displayed on the
screen.
4.
Fan control: when fan starts to work, the icon of fan
to work, the fan is on. Fan stops when compressor or heating stops.
for 5 seconds to cut off the system; press the on/off key again to display the
to turn on the light icon is displayed on the screen; When the light is
button to enter room temperature regulating state, press the
to change the controlling temperature (the default is 12 ℃). Press the
will appear in the screen. When the compressor or heating start
38

Advertisement

Table of Contents
loading

Table of Contents