GE GEP5.0-3-10 User Manual page 53

4-20kw three phase
Hide thumbs Also See for GEP5.0-3-10:
Table of Contents

Advertisement

10 Technical Parameters
Technical Data
AC Grid Frequency Range
(Hz)
Max. Output Current (A)
Max. Output Fault
Current (Peak and
Duration) (A)
Inrush Current (Peak and
Duration) (A)
Nominal Output Current
(A)
Power Factor
Max. Total Harmonic
Distortion
Maximum Output
Overcurrent Protection
(A)
Efficiency
Max. Efficiency
European Efficiency
CEC Efficiency
Protection
PV Insulation Resistance
Detection
Residual Current
Monitoring
PV Reverse Polarity
Protection
Anti-islanding Protection
AC Overcurrent
Protection
AC Short Circuit
Protection
AC Overvoltage
Protection
DC Switch
DC Surge Protection
AC Surge Protection
AFCI
GEP10-3-10
GEP10-3-AU10
45~55 /
45~55 / 55~65
55~65
16.0
16.0
32A@5ms
32A@5ms
80A@50us
80A@50us
14.5
14.5
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
<3%
38.37
38.37
98.3%
98.3%
97.6%
97.6%
97.8%
98.0%
User Manual V1.0-2022-05-10
GEP12-3-10
45~55 / 55~65
19.1
36A@5ms
150A@50us
17.3
<3%
88.93
98.4%
97.8%
98.0%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Type II
Type III (Type II Optional)
Optional
48
GEP15-3-10
GEP20-3-10
45~55 /
45~55 / 55~65
55~65
24.0
32.0
41A@5ms
54A@5ms
150A@50us
150A@50us
21.7
29.0
<3%
<3%
88.93
88.93
98.4%
98.4%
97.8%
97.8%
98.0%
98.0%

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gep10-3-au10

Table of Contents