GE GEP5.0-3-10 User Manual page 34

4-20kw three phase
Hide thumbs Also See for GEP5.0-3-10:
Table of Contents

Advertisement

User Manual V1.0-2022-05-10
Connecting the Communication Cable(RS485, Meter, and DRED)
Connect the RS485 cable, meter cable, and DRED cable using a 6PIN communication terminal
as follows.
1
25mm
3
M2
0.3~0.4N·m
4
RS485/
Meter
6.5mm
COM
NOTICE
DRED
2
RS485/Meter (COM2)
1: RS485 B
2: RS485 B
3: RS485 A
4 RS485 A
5: Meter +
6: Meter -
Do not remove the pre-installed terminal when
the DRED function is unused. Install the terminal
back to the inverter when the DRED function is
not to be used. The inverter cannot be grid-tied if
the terminal is removed.
29
06 Electrical Connection
DRED (COM3)
1: DRM1/5
2: DRM2/6
3: DRM3/7
4: DRM4/8
5: REFGen
6: Com/DRM0
WARNING