I-310e – UserManual

Installation

Cover Removal

To open the Model I-310e use a coin in the slot on the
bottom to release the snap. Lift the cover up slightly to
disengage the closure and remove cover with a downward
motion to clear the catch at the top of the unit.
The locations of controls and terminals on the main circuit
board are shown in the Figure 2 on page 4.

Mounting

The Model I-310e is designed for flush mounting with two
fasteners. The locations of the mounting points (shown in
Figure 1) allow direct mounting on a standard simplex
(single circuit) junction box. There is a wiring cutout in the
center of the unit near the terminal strips.