Intec PolyGard 2 SC2 User Manual

Toxic (e-), combustible (p-) and infrared (i-co2) gases

Advertisement

Quick Links

Toxic (E-), Combustible (P-) and Infrared (I-CO
) Gases
2
PolyGard
2 SC2 & AT6 Sensors
®
User Manual
November 2019
April 13, 2020 – Revision
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

Advertisement

Table of Contents
loading

Summary of Contents for Intec PolyGard 2 SC2

  • Page 1 Toxic (E-), Combustible (P-) and Infrared (I-CO ) Gases PolyGard 2 SC2 & AT6 Sensors ® User Manual November 2019 April 13, 2020 – Revision INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 2: Table Of Contents

    13 Intended Product Application ........................17 13.1 Installers’ Responsibilities ........................17 13.2 Maintenance ............................17 13.3 Limited Warranty ........................... 17 INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 3: Functional Description

    • Corrosive substances, such as halogenated hydrocarbons. • Catalytic poisons, such as sulfur and phosphor compounds, silicon compounds, metal vapors. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 4: Sensor Element For Combustible Gases

    • Corrosive substances, such as halogenated hydrocarbons • Catalytic poisons, such as sulphur and phosphor compounds, silicon compounds, metal vapours INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 5: Installation

    4,000 Ceiling ACCESSORIES XC-CAP (1) Replacement protective sensor cap PG2- (1) Duct mounting kit for SC2 / AT6 sensor DUCTKIT INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 6: Electrical Connection

    30-90% of the measuring range. Rest is synthetic air. • Extraction set consisting of gas pressure regulator and flow meter • Calibration adapter with tube; CONKIT-PG2. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 7: Installation Of Sensor Cartridge

    • Symptoms: Dizziness, headache and nausea. • Procedure if exposed: Remove victim to fresh air at once, seek medical attention. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 8: Calibration Process

    Calibration will not be possible when the sensitivity of the sensor drops to 40% or lower; the Sensor Cartridge must be replaced. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 9: Exchange Of Sensor Cartridge

    Remove dust deposits, especially at the gas inlet. • The filter at the gas inlet has to be replaced if extremely dirty. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 10: Service And Calibration

    (adjustable in system parameters -> error time, value range> 1) until the calibration is repeated. Performing the calibration automatically deletes this message. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 11: Troubleshooting

    Check SC at input 2, replace it SC Input 3 ≠ stored type Wrong SC type at input 3 Check SC at input 3, replace it INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 12: Cross-Sensitivity Data

    Please check the SC2 datasheet for the latest specifications. Available at: http://inteccontrols.com/gas-detection/SC2.html http://inteccontrols.com/gas-detection/SC2.pdf 9.2 AT6 Please check the AT6 datasheet for the latest specifications. Available at: http://inteccontrols.com/gas-detection/AT6.html http://inteccontrols.com/gas-detection/AT6.pdf INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 13: Sensor Element

    Reading INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 14 The sensitivity of Pellistor sensors can be influenced by substances containing silicon compounds and even poisoned/destroyed by them. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 15: Cross Sensitivity - Sensor Cartridge (Sc2 / At6) / Sensor Element

    1 The table doesn’t claim to be complete. Other gases, too, can have an influence on the sensitivity. The mentioned cross sensitivity data are only reference values valid for new sensors. 2 Cross sensitivities valid for all measuring ranges of the sensor. INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 16: Figures

    Fig. 1 Fig. 3 Printed Circuit Board with Sensor Cartridge SC2 connection to Printed Circuit Board Fig. 2 Calibration adapter, CONKIT-PG2 INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com...
  • Page 17: Part Disposal

    13.3 Limited Warranty INTEC Controls warrants the SC2 / AT6 devices for a period of one (1) year from the date of shipment against defects in material or workmanship. Should any evidence of defects in material or workmanship occur during the warranty period, INTEC Controls will repair or replace the product at their own discretion, without charge.

This manual is also suitable for:

Polygard 2 at6

Table of Contents