Atex; European Atex Directive - Ransburg 9040 Service Manual

Low voltage control unit kit for the esta-quick and evolver se applicators
Table of Contents

Advertisement

9040 Low Voltage Control Unit Kit- Atex
EUROPEAN ATEX DIRECTIVE 94/9/EC, ANNEX II, 1.0.6
The following instructions apply to equipment
covered
by
certificate
11ATEX5240X:
1. The equipment may be used with flammable
gases and vapors with apparatus groups II and
with temperature class T6.
2. The equipment is only certified for use in
ambient temperatures in the range +12.8C to
+40C and should not be used outside this range.
3. Installation shall be carried out by suitably
trained personnel in accordance with the
applicable code of practice e.g. EN 60079-
14:1997.
4. Inspection
and
equipment shall be carried out by suitably
trained personnel in accordance with the
applicable code of practice e.g. EN 60079-17.
5. Repair of this equipment shall be carried out
by suitable trained personnel in accordance with
the applicable code of practice e.g. EN 60079-19.
6. Putting into service, use, assembling, and
adjustment of the equipment shall be fitted by
suitably trained personnel in accordance with
the manufacturer's documentation.
Refer to the "Table of Contents" of this service
manual:
a. Installation
b. Operation
c. Maintenance
d. Parts Identification
7. Components to be incorporated into or used
as replacement parts of the equipment shall be
fitted by suitably trained personnel in accordance
with the manufacturer's documentation.
5
number
Sira
maintenance
of
this
8. The certification of this equipment relies upon
the following materials used in its construction:
If the equipment is likely to come into contact with
aggressive substances, then it is the responsibility
of the user to take suitable precautions that
prevent it from being adversely affected, thus
ensuring that the type of protection provided by
the equipment is not compromised.
Aggressive substances: e.g. acidic liquids or
gases that may attack metals, or solvents that
may affect polymeric materials.
Suitable precautions: e.g. regular checks as
part of routine inspections or establishing from
the material's data sheets that it is resistant to
specific chemicals.
Refer to "Specifications" in the "Introduction"
section:
a. All fluid passages contain stainless
steel or nylon fittings.
b. High voltage cascade is encapsulated
with a solvent resistant epoxy.
9. A recapitulation of the certification marking
is detailed in the "Atex" section, on the next
page, drawing numbers: 72562 and 80075.
10. The characteristics of the equipment shall
be detailed e.g. electrical, pressure, and voltage
parameters.
The manufacturer should note that, on being
put into service, the equipment must be
accompanied by a translation of the instructions
in the language or languages of the country in
which the equipment is to be used and by the
instructions in the original language.
CP-11-01

Advertisement

Table of Contents
loading

Related Products for Ransburg 9040

Table of Contents