Ransburg 9040 Service Manual page 7

Low voltage control unit kit for the esta-quick and evolver se applicators
Table of Contents

Advertisement

AREA
Tells where hazards
may occur.
Spray Area /
High Voltage
Equipment
CP-11-01
9040 Low Voltage Control Unit Kit- Safety
HAZARD
Tells what the hazard is.
This is a high voltage device that Parts being sprayed must be supported on conveyors
can produce electrical arcs
capable of igniting coating
materials.
SAFEGUARDS
Tells how to avoid the hazard.
or hangers and be grounded. The resistance between
the part and ground must not exceed 1 Mega .
(Reference NFPA-33, EN 60079.)
A safe distance must be maintained between the parts
being coated and the atomizer . A distance of at
least 1 inch for each 10 KV of power supply output
voltage is required at all times.
Parts must be supported so that they will not swing
and reduce the clearance specified above.
All electrically conductive objects in the spray area,
with the exception of those objects required by the
process to be at high voltage, must be grounded.
Unless specifically approved for use in hazardous
locations, the power supply and other electrical
equipment must not be used in Class I, Division 1 or
2 locations or in Zone 1.
4