Ransburg 9040 Service Manual page 15

Low voltage control unit kit for the esta-quick and evolver se applicators
Table of Contents

Advertisement

For installations where it is required to run the AC
input wiring in conduit, perform the following:
1. Ensure the AC line cord is unplugged and
remove the AC Inlet Receptacle wiring from
1TB-L1, 1TB-N and 1TB-Ground (see Figure 2
for AC input wiring locations).
Figure 2: Terminal Block One (1TB)
!
W A R N I N G
> Always double check that the control unit
is unplugged from its AC outlet before
working with any internal wiring connected to
1TB-L1, 1TB-L2, 1TB-N, 1FU, 1SW, or 8PL.
3. Remove the mounting hardware from the AC
Inlet Receptacle and remove it from the rear of
the control unit.
4. Install the Conduit Adapter Plate (supplied)
in the hole where the AC Inlet Receptacle was
removed (see Figure 3).
5. Install the AC line cord through the Conduit
Adapter Plate using conduit and wire to TB1 as
follows:
Hot/Line
Neutral/Common
Ground
CP-11-01
9040 Low Voltage Control Unit Kit- Installation
to
1TB-L1
to
1TB-N
to
1TB-Ground
Conduit Adapter Plate
Figure 3: Installation of Conduit
Adaptor Plate
NOTE
When using conduit to route the AC
>
input wiring to the control unit, the last
several feet of conduit attached to the
control unit should be of a flexible type,
such that the control unit module can
still be slid out of the enclosure for
testing and setup purposes.
The
9040
Cascade
universal input voltage between 90 and 264
VAC. There is no need to change any switch
settings when changing input from 115 to 230
VAC or vice-a-versa.
control
unit
accepts
12