9040 Low Voltage Control Unit Kit- Operation

OPERATION

!
W A R N I N G
> The user MUST read and be familiar
with the SAFETY PRECAUTIONS and
SAFETY SECTIONS of this manual and
the
Ransburg safety literature therein
identified BEFORE OPERATING the 9040
Cascade control unit.
Item
Description
1
Kilovolt Meter
2
AC Power Indicator
3
High Voltage On Indicator
4
Microamp Meter
23
> The electrical discharge that is available
from
applicator must not exceed 0.25 mJ of
energy. To achieve this limit, any flow of
energy from the paint supply through the
paint line to the applicator electrode must
be prevented by grounding the paint line at
the applicator handle or body.
> Verify that the applicator is actually
grounded before operating it! (See the
appropriate applicator manual.) If improper
readings are obtained, check that the
control unit is grounded. (See "Ground
Test Procedures" in the "Maintenance -
Troubleshooting" section of this manual.)
Figure 9: Operating Controls
Item
5
6
7
8
!
W A R N I N G
the
charging
electrode
Description
AC Power On-Off Switch
High Voltage Adjust Knob
Cable Fault/hook OFF Indicator
Overload Indicator and Reset Switch
of
the
CP-11-01