an alarm triggered recording ends at 11:00, and if you set the post-record time as 5 seconds, it
records till 11:00:05.
Expired Time: The expired time is period for a recorded file to be kept in the HDD. When the
deadline is reached, the file will be deleted. If you set the expired time to 0, the file will not be
deleted. The actual keeping time for the file should be determined by the capacity of the HDD.
Redundant Record/Capture: By enabling redundant record or capture you save the record and
captured picture in the redundant HDD. See Chapter Configuring Redundant Recording and
Capture.
Record Audio: Check the checkbox to enable or disable audio recording.
Video Stream: Main stream and sub-stream are selectable for recording. When you select
sub-stream, you can record for a longer time with the same storage space.
3)
Click Apply to save the settings.
You can enable the ANR (Automatic Network Replenishment) function via the web browser
(Configuration > Storage > Schedule Settings > Advanced) to save the video files in the IP camera when the
network is disconnected, and synchronize the files to the NVR when the network is resumed.
The redundant record/capture is used when you want to save the record files or captured pictures in the
redundant HDD. You must configure the redundant HDD in HDD settings. For detailed information,
see Chapter 13.4.2.
The parameters of Main Stream (Event) are read-only.
3. Parameters Settings for Sub-stream
1)
Enter the Sub-stream tab page.
2)
Configure the parameters of the camera.
3)
Click Apply to save the settings.
4. Parameters Settings for Capture
1)
Select the Capture tab.
Network Video Recorder User Manual
Figure 5. 5 Sub-stream Parameters
77