Install Tube Extension To Hopper; Install Hose To Hopper Assembly; Install Hose To Blower Assembly; Operation - Ferris SNAPPER PRO EZ Dump Operator's Manual

Grass collection systems
Table of Contents

Advertisement

(B, Figure 44). The latch (A, Figure 45) should be high
enough so that it clears the locking pin (B) as shown in
inset 2, Figure 45.
45
3. If both of the above detailed conditions are not met,
adjust the dump handle linkage rod (C, Figure 44) by
loosening the jam nuts (D) and shortening or lengthening
the linkage rod until both conditions detailed above are
met.
4. Once the proper adjustment is achieved, re-tighten the
jam nuts.

Install Tube Extension to Hopper

1. Remove the three (3) screws (A, Figure 46) and 1/4
nylock flange nuts (B) screwed into the hopper.
46
2. Install the extension tube (C) to the hopper using three (3)
1/4-20 X 1" bolts (D), 1/4 SAE washers (E), and 1/4-20
nylock flange nuts (B).
3. Install the three (3) screws (A) and 1/4 nylock flange nuts
(B) into the extension tube.

Install Hose to Hopper Assembly

The procedure for installing the hose is the same whether
it is installed directly to the hopper or if it is installed to the
extension tube.
1. Install a thin layer of grease to the flange of the hose
elbow assembly (A, Figure 47).
47
2. Install the flexible hose (B) into the clear hose assembly
(C) and secure in place with a new clamp.
3. There are three bolts in the hopper assembly. Align these
bolts with the large part of the slots in the elbow assembly
when installing to the hopper assembly and rotate the
elbow assembly clockwise to lock in place.
4. Slide the flexible hose and clear hose assembly into the
elbow assembly.

Install Hose to Blower Assembly

1. Position the latches (A, Figure 48) 2-1/4" (5,72 cm) from
the end of the blower assembly (B) and they should be on
the sides of the blower 180° apart.
48
2. Using a 3/16" (0.48 cm) drill bit, drill the four holes for the
latches.
3. Install the latches to the blower assembly and secure in
place using the four (4) pop rivets, which are installed
from the inside of the blower mount to the outside.
4. Attach the hose assembly to blower assembly and secure
in place using the rubber straps.

Operation

19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snapper pro ez dump xl

Table of Contents