WarmFlow 50/70 Installation & Servicing Manual page 20

Table of Contents

Advertisement

5.6.2 Honeywell 'S' Plan – Independant CH&DHW (fully pumped)
Note: Bluebirds and Whitebirds should be treated as simple boilers and wired
as per the control pak manufacturers instructions.
240V
50Hz
L
N
E
Before fitting the programmer remove loop 'A' from 15 and 16 and loop 'B' from 15 and
6 on the terminal block. The switch on the programmer is to be set to 'P'.
V4043H ZONE VALVE HTG
MOTOR
G/YELLOW
T6360B
ROOM STAT
2
1
3
1
2
3
4
5
Page 18
V4043H ZONE VALVE DHW
BLUE
MOTOR
L641A
CYLINDER
STAT
2
1
C
6
7
8
9
10
10 WAY
JUNCTION BOX
N
E
L
PUMP