P.i.r. detector

Advertisement

Quick Links

This P.I.R. motion detector is
used to protect interiors. It detects
any movement of objects with a
temperature close to that of the
human body.
The signal from the sensor is
electronically analyzed. This ensures
that the detector provides excellent
sensitivity and at the same time false
alarms are basically eliminated. The
detection
analysis
rate
can
adjusted to increase its immunity if
the
JS-20
is
installed
in
problematic location.
The standard lens in the detector
can be replaced with an optional
corridor or pet immune lens. Extra
terminals (GBS) can be used to
facilitate wiring of the detector.
The JS-20 distinguishes itself
with excellent RF immunity.
It can be mounted on a flat wall
or in a corner.
Installation
This detector is designed for
indoor applications. It can be mounted on a flat wall or in a corner. Do not
place the detector close to any heating/cooling vents or near any other object
that often change temperature. The detector must have an unobstructed view
of the protected area.
1. Open the cover of the detector (press in the plastic tab on the bottom
part of the detector's housing with a screwdriver).
2. Remove the PCB by pressing the flexible tab inside the housing.
3. Punch through the pre-formed holes for cables and screws.
4. Attach the housing to the wall (2.5 meters above the floor).
5. Return the PCB into the rear housing and connect the cable wires to
the terminals.
6. Attach the cover.
Note: Avoiding touching or scratching the PIR sensor!
Terminals
+12V, GND
power supply
PIR, PIR
PIR alarm output (normally closed)
TMP, TMP
TAMPER output (normally closed)
GBS, GBS
auxiliary terminals – useful when wiring (see examples)
Jumpers
LED
the LED indicator can be disabled by opening this jumper
DETECTION
by opening this jumper you can set a higher rate of analysis
and increase the immunity of the detector. This setting is
suitable for problematic locations with sudden temperatures
changes or electromagnetic interference. Reaction of the
detector will be slightly slower in this setting.
Detector testing
After switching on the power, wait for 1 minute. During this period the
detector initializes and stabilizes its parameters (LED will be on if not
disabled).
Each detected movement will be indicated by the detector's LED (if not
disabled)
Confirm that the detector covers the protected area as you expected.
Lenses
Standard lens that is supplied with the JS-20 Largo detector covers an
area of 120 degrees / 12 meters.
JS-20 LARGO,P.I.R. detector
JS-20 „LARGO" P.I.R. detector
be
a
For special applications other lenses can be used. Optional lenses for long
corridors and areas with small animals are supplied separately.
The Pet lens is marked JS-7910. This lens prevents animals smaller then
40 cm to be detected by the detector. The working range of this lens is
reduced to 7 meters. It is recommended to test this lens carefully with the
animal when installing the system, in order to prevent false alarms.
The Corridor lens is marked JS-7904. The working range of this lens is
25 meters long and only 3 meters wide. It is recommended to test the
detector's sensitivity carefully when installing it into a corridor.
The curtain lens is marked JS-7902. By using this lens the PIR detector's
working range is restricted to a "curtain". After using this lens, it is for
example possible to secure part of a room etc. During the installation it is
necessary to test the working range very carefully.
Lens characteristic diagrams can be seen in documents supplied with
the lens or on the Jablotron website
Note: Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the producer
after usage.
Specification
Power supply:
Power consumption (LED off):
Maximum consumption (LED on):
Terminals size:
Mounting height:
Detection range:
Initialization:
Alarm output:
Tamper output:
Environment - class
Operating temperatures
Security level
EMC
JABLOTRON ALARMS a.s. hereby declares that the JS-20 is in a
compliance with the relevant Union harmonisation legislation:
Directives No: 2014/30/EU, 2011/65/EU. The original of the
conformity assessment can be found at www.jablotron.com -
Section Downloads.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
manufacturer after use.
www.jablotron.com
.
12 V DC ± 25%
max. 10 mA
max. 35 mA
max. 1 mm
2.5 m above floor
120° / 12 m (standard lens)
aprox. 1 minute
normally closed, max. 60V / 50 mA,
internal resistance max.30 Ohm
normally closed, max. 60 V / 50 mA,
internal resistance max.16 Ohm
II. – general indoor, (EN 50131-1)
-10 to +40 °C
grade 2, EN 50131-1, EN 50131-2-2
EN 50130-4, EN 55022
MGD51208
2

Advertisement

loading

Summary of Contents for jablotron LARGO JS-20

  • Page 1 EN 50130-4, EN 55022 Detector testing JABLOTRON ALARMS a.s. hereby declares that the JS-20 is in a compliance with the relevant Union harmonisation legislation: • After switching on the power, wait for 1 minute. During this period the Directives No: 2014/30/EU, 2011/65/EU.
  • Page 2 Examples of wiring the JS-20 Largo detector using end-of-line resistors and double end-of-line resistors (Auxiliary GBS terminals are used to facilitate the wiring) Example of wiring of several JS-20 Largo detectors into the double EOL loop (Auxiliary GBS terminals are used to facilitate wiring) Example of wiring of several JS-20 Largo detectors into the EOL loop (Auxiliary GBS terminals are used to facilitate the wiring) JS-20 LARGO,P.I.R.