4-2-14) When Csz Room Damper Does Not Work - Samsung RL60GG Series Service Manual

Bottom mounted freezer type
Table of Contents

Advertisement

4. TROUBLESHOOTING

4-2-14) When CSZ Room Damper does not work

MICOM & CSZ DAMPER STATE
MICOM
48
47
46
DAMPER
CLOSE
5V
0V
0V
...ING
0V
-
5V
OPEN
5V
5V
0V
* Note
Its operations can change based on
its functions.
DAMPER is under a
working condition.
CSZ temp satisfies the
Shift Set Temp
[Set lower than the current temp]
MAIN PCB Connector CN75
is inserted normal
Remark
Voltage is output from
MICOM Pin #46,47,48
DAMPER is normal
Replace PCB MAIN
Start
No
Yes
No
set temp
Yes
No
Yes
No
Yes
No
Yes
Normal
68
Forced Operation, Temp Increased
Check Wiring & PCB MAIN
Check Connector CN75
Check Cold Solder, Replace PCB
Replace DAMPER