Briggs & Stratton SIMPLIPHI Installation Manual page 38

6kw hybrid inverter
Table of Contents

Advertisement

NOTE: If backlight shuts off, you can activate by touching any button on the screen.
12.10– LCD Settings
After touching and holding "UP" and "DOWN" button for
Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" button to confirm the
selection or ESC button to exit.
Prog ram
Description
Exit Setting
00
Mode
01
Output Voltage
Output
02
Frequency
03
Battery Type
Maximum
04
Charging
Current
Maximum Utility
05
Charging
Current
Maximum
06
Discharging
Current
© SIMPLIPHI POWER
2 seconds,
Selectable option
Escape
110Vac
120Vac(default)
60Hz
50Hz(default)
User-Defined(default)
When "User Defined" is selected as a battery
type, battery charging voltage and low DC
voltage cutoff can be set up in program 4, 7,
8 and 9 manually
CAN
When" CAN" is selected as a battery type,
programs 4, 7, 8 and 9 will be automatically
set up for SimpliPHI battery
CAN
60A(default)
Setting range is 1A, then from 10A to
120A. Increment of each click is 10A
To configure total charging current for solar
and utility chargers. (Max. charging current =
utility charging current + solar
charging current)
60A(default)
Setting range is from 10A to 120A. Each click
will increment by 10A
100A(default)
Setting range is from 10A to 150A. Each click
will increment by 10A