Step 4: Check for correct polarity on the connection cable from PV modules and PV input connectors. Then,
connect the positive pole (+) of connection cable to the positive pole (+) of PV input connector. Connect the
negative pole (-) of the connection cable to the negative pole (-) of the PV input connector.
Step 5: Tie in your EPO or RSD button to the RSD terminals. Once PV is connected and all polarity
verified, turn the PV Disconnect switch on the side of the inverter to the "ON" position. Once the
inverter is up and running test your rapid shutdown procedure and verify it is functioning properly.
WARNING!
TO USE APPROPRIATE CABLE FOR PV MODULE CONNECTION. TO REDUCE RISK OF
INJURY USE #12AWG OR #10AWG WIRE FOR PV CONNECTIONS.
WARNING!
LETHAL ELECTRIC SHOCK.
CAUTION!
THE ON POSITION. WHEN PV MODULES ARE EXPOSED TO SUNLIGHT, THEY MAY BE
GENERATING DC VOLTAGE.
9.0 – Generator Connection
The SimpliPHI Inverter has a built-in Automatic Generator Start (AGS) relay that will enable you to connect a
two-wire start generator to the inverter. Based on battery voltage settings within the inverter, you can trigger
© SIMPLIPHI POWER
IT IS VERY IMPORTANT FOR SYSTEM SAFETY AND EFFICIENT OPERATION
NEVER DIRECTLY TOUCH TERMINALS OF THE INVERTER. IT CAN CAUSE
DO NOT TOUCH THE INVERTER COMPONENTS IF THE PV SWITCH IS IN
| 21 |
REV2022007071630