Sharp PN-V601 Installation Manuallines page 9

Hide thumbs Also See for PN-V601:
Table of Contents

Advertisement

Precautions for temperature and clearance space 4
Space requirement 3
2.The case of reducing clearance space and operating temperature
The timing of fan replacement (*2) becomes shorter to 2.5 years in the following condition of clearance space and operating
temperature.
For case of 3 x 3 multi-screen displays
"Fan rotation speed" Setting
Auto (Variable: default setting)
For case of 5 x 5 multi-screen displays
"Fan rotation speed" Setting
Auto (Variable: default setting)
*2 The timing of fan replacement is used as a guideline.
The actual life may vary depending the operating time, change of ambient temperature, environment such as amount of dust, or regular
maintenance.
Even if a fan on the LCD monitor has trouble, the neighbor fan supplements its operation. Therefore, the LCD monitor correctly works.
Above life is described as rough guide and it shall not warrant the life. Even within the warranty period, the replacement of fan caused
by failure is charged. The warranty does not include pre-mature fan failure.
CONFIDENTIAL
Clearance space at the back side
3.5cm or more
10cm or more 20cm or more 30cm or more 40cm or more
33
26
38
Clearance space at the back side
3.5cm or more 10cm or more 20cm or more 30cm or more 40cm or more 50cm or more 60cm or more
24.5
30.5
33
(Unit: degree celsius )
39
40
35
37.5
39
PN-V601 Installation Guidelines <Rev1.4 > September.30, 2010
8
CONFIDENTIAL
40

Advertisement

Table of Contents
loading