Workstation
When using the appliance, the operator
stands in front of it.

Function

The detergent in the container is heated by
the heating element and transported by the
pump to the cleaning tools. These can then
be controlled via the corresponding shut-off
valves.
Solid dirt particles are held back by the
sieve in the rinsing floor or in the underlying
filter mat.
Grease and oily dirt is rinsed back into the
container and is there degraded by the mi-
crobes into carbon dioxide and water.
The microbes are first caught in the filter
mat and are then transported by the liquid
detergent into the container. The liquid de-
tergent must be heated in the container so
that the microbes can function optimally.

Safety instructions

Please read the operating instructions
for your machine before using it, and
pay particular attention to the following
safety instructions.
Warning and information plates on the
machine provide important directions
for safe operation.
In addition to the information contained
in the operating instructions, all statuto-
ry safety and accident prevention regu-
lations must be observed.
Symbols in the operating instruc-
Danger
Immediate danger that can cause severe
injury or even death.
Warning
Possible hazardous situation that could
lead to severe injury or even death.
Caution
Possible hazardous situation that could
lead to mild injury to persons or damage to
property.
16
tions
Symbols on the machine
!
Power connection
Danger
Danger of injury by electric shock.
The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Check the power cord with mains plug for
damage before every use. If the power cord
is damaged, please arrange immediately
for the exchange by an authorized custom-
er service or a skilled electrician.
It is recommended that you connect this
device to a socket that has a 30 mA pro-
tection switch against wrong currents.
Please use the mains cable prescribed
by the manufacturer; the same is also
applicable when you replace the ca-
bles. For type details see spare parts
list.
Never touch the mains plug with wet
hands.
Make sure that the power cord or exten-
sion cables are not damaged by run-
ning over, pinching, dragging or similar.
Protect the cable from heat, oil, and
sharp edges.
The extension cable must have the
cross-section listed in the circuit plan
and be protected against spraying wa-
– 2
EN
Danger
Risk of electric shock. The
casing must only be
opened by electricians.