Error diagnosis

Error description
Two-time activation of motor at battery
insertion
Pairing not possible
No visual or acoustical signals
on wall module
No communication with wall module
(no engaging, no status signals)
No (electronic) engaging, however
status signals are transmitted to wall
module
No (mechanical) engaging, however
status signals are transmitted to wall
module
No engaging via cylinder
Miscellaneous
8

Disposal

Radio lock PRIME OFFICE 2170 and wall module FMIO B 5528 0110 must be disposed of as electronic waste
at a spezial waste collection site.
The battery must be expertly disposed of at appropriate collection sites.
The packing must be disposed separately.
15
Cause
• Lock is not paired
• Lock has already been paired with
another wall module
• Pairing time expired
• Voltage supply failing
• Defective electronic component
• Wrong Pairing adress
• Battery empty
• Battery inserted in wrong way
• Lock and wall module not within
radio range
• Battery empty
• Poor radio communication
• Lock seized
• Handle not in normal position
• Mode 'permanent release' is active
• Defective mechanical component
0-45648-3E-0-GB, modif. 1, sheet 15/20, Mod. No. G24578, www.g-u.com 01/2011
Correction
• Perform ‚Pairing'
• Assign lock to correct wall module
or:
• Perform ‚Repairing'
and repeat ‚Pairing'
• Reinsert battery and
repeat ‚Pairing'
• Check voltage supply of wall module
• Replace wall module,
perform ‚Repairing',
repeat 'Pairing'
• Perform ‚Repairing',
repeat ‚Pairing'
• Insert new battery
• Verify correct battery polarity
• Reduce distance between lock and
wall module
• Exchange battery
• Reduce distance between lock and
wall module
• Slightly loosen fastening screws of
fittings
• Verify tightening torque of clamping
screws
• Handle too heavy
use handle with
hold-up spring
• Verify fittings / attachment of fittings
• Quit 'Permanent release'
and try again
• Exchange lock
• Call BKS service
Chapter
6.1
1.2
6.2;
6.1
5;
6.1
1.1;
4.3
6.2;
6.1
6.2;
6.1
5
5
4.3
5
4.3
4.2
4.2
4.2
2.2.2.3