Download Print this page

Cisco CompactFlash Adapter Installation Manual page 18

Cisco systems compactflash adapter installation guide

Advertisement

Installing the SP Bootflash Memory Upgrade Kit
Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the
Step 4
following two sets of steps:
Horizontal slots
Position the supervisor engine in the slot. (See
a.
module carrier with the slot guides on each side of the slot.
b.
Carefully slide the supervisor engine into the slot until the EMI gasket along the top edge of the
module makes contact with the module in the slot above it and both ejector levers have closed to
approximately 45 degrees with respect to the module faceplate. (See
Using the thumb and forefinger of each hand, grasp the two ejector levers and press down to create
c.
a small 0.040 inch (1 mm) gap between the supervisor engine's EMI gasket and the module above
it. (See
Note
While pressing down, simultaneously close the left and right ejector levers to fully seat the
d.
supervisor engine in the backplane connector. The ejector levers are fully closed when they are flush
with the module faceplate. (See
Note
Tighten the two captive installation screws on the supervisor engine.
e.
Note
Power up your system.
f.
Note
Verify that the Supervisor Engine 720 STATUS LED is lit.
g.
Periodically check the STATUS LED. If the STATUS LED changes from orange to green, the
module has successfully completed the boot process and is now online.
If the STATUS LED remains orange or turns red, the supervisor engine has not successfully
completed the boot process and may have encountered an error.
Cisco CompactFlash Adapter for Bootflash Upgrade Installation Note
18
Figure
8.)
Do not press down too forcefully on the levers because they will bend and be damaged.
Figure
Failure to fully seat the module in the backplane connector can result in error messages.
Make sure that the ejector levers are fully closed before tightening the captive installation
screws.
Depending on how your system bootstring is configured, your system might stay in
ROMMON. To boot the system from the CF adapter, enter the boot bootdisk: command.
Once you install the CF adapter, you must define the Cisco IOS bootstring as
boot system flash sup-bootdisk:[image name]
With SP ROMMON Release 8.4(2), the bootstring has to be defined as sup-bootdisk:. SP
ROMMON releases later than 8.4(2) only accept the bootstring defined as sup-bootflash:.
Figure
7.) Make sure that you align the sides of the
8.)
Figure
8.)
78-17277-05

Advertisement

loading