Set Vender Type - Dixie Narco 501E Technical Manual

Pepsi-cola high visibility vender for ht2 venders produced beginning production run 6730bz for ht3 venders produced beginning production run 6757dz
Hide thumbs Also See for 501E:
Table of Contents

Advertisement

CONTROLLER PROGRAMMING
Setting The Vender Type
When installing a service control board that has not
been installed in a vender, the control board needs
to set the vender type to recognize and perform
proper
space-to-sales
operations.
To set the vender type:
1. Remove power to the vender.
2. Remove the existing control board.
3. Install the new control board.
4. Power-up the vender and the display will
scroll "Set Model Number".
5. Press button 1 and the machine will display
the model number available "501E".
6. Press buttons 1 and 2 simultaneously, this
will allow the user to cycle through the
available model numbers for that machine
type. Once the desired model number is
displayed "HVV", pressing button 1 will set
this type.
Note:
If the incorrect model number is set, the
machine will not have the correct default
space-to-sales arrangement.
should power down the unit, unplug the
battery, and reset RAM. The user should
then begin the model number set routine
again.
options
and
vending
The user
Factory Default Setting
Selection #
Column #
1
1
2
1
3
2
4
3
5
4
6
4
7
5
8
6
9
7
10
8
11
9
12
9
21