TECHNICAL DATA

The fan is designed for operation in an enclosed area at ambient temperatures from +1 °C up to +40 °C.
The fan is rated as a class I electric appliance.
The fan design is regularly improved, so some models may slightly differ from those ones described herein.
Voltage [V/Hz]
Power [W]
Current [A]
Maximum air capacity [m
Maximum air capacity [l/s]
RPM
Sound pressure level at 3 m distance [dB(A)] through a
casing in free space
Transported air temperature [°С]
Degree of fan protection
Degree of motor protection
SEC class (+speed control and external sensor)
6
OVERALL AND CONNECTING DIMENSIONS OF THE FANS
Model
Ø D
KSA 100-2E
99
KSA 125-2E
124
KSA 150-2E
149
KSA 160-2E
159
KSA 200-4E
199
MAIN TECHNICAL PARAMETERS OF THE FANS
/h]
3
Dimensions [mm]
В
Н
Н1
294
260
309
136
310
260
309
154
350
295
344
183
350
295
343
183
436
361
409
233
KSA 100-2E
KSA 125-2E
130
155
0.60
0.70
425
505
118
140
2870
2870
36.1
38.3
C
C
Weight
[kg]
L
L1
184
4.2
206
4.6
231
6.3
231
6.3
282
8.3
KSA 150-2E KSA 160-2E KSA 200-4E
1~230/50
335
335
1.50
1.50
750
750
208
208
2870
2870
39.4
37.9
-25...+40
IPX2
IP44
D
D
www.ventilation-system.com
KSA
115
0.50
640
178
1350
29.1