Install the smoke detector

Warning: Ensure that the main power
supply is disconnected at the
distribution panel before installing the smoke
detector.
1. Unclip the base plate from the detector.
2. Using suitable fasteners, mount the base
plate on the wall within 10' of the High
Power Connector, and within 4" to 12"
from the ceiling. Do not mount to the
ceiling.
3. Clip the detector to the base plate.
4. Route the wiring to the RJ45 jack on the
right side of the High Power Connector
and connect to the Ethernet socket.
5. Cut the wire to the appropriate length
and terminate using the RJ45 connector,
ensuring that the brown wire is
connected to Pin 1 as illustrated here.
connect brown
wire to Pin 1
6. Plug the smoke detector cable into the
RJ45 jack on the right side of the High
Power Connector.
Step-by-step installation instructions
7. Using suitable fasteners, secure the
wiring to the wall.

Mount the cable hanger

The cable hanger must be mounted so that
the connector used to connect the High
Power Connector to the vehicle is stored
between 18" and 48" from the ground and
free of obstructions.
Mount the cable hanger using two #10 2 1/2"
lag screws for masonry walls, or two RSSTM
(Rugged Structural Screws) for stud walls.

Inspect the cable connection

Check to ensure the charge cable connection
wasn't detached during installation.
7"
1. Ensure the connections to the disconnect
mechanism are fully seated.
2. Ensure that the lower mounting plate is
flush with the bottom of the unit.

Re-install the front cover

1. Mount the front panel backwards on the
two left-hand screws.
2. Connect the ground strap between the
main housing and the front cover.