Installation

Placement

!
NOTE: It is recommended that the bottom of the unit be mounted between 5" (13 cm) and 40" (102 cm) from the
ground to maintain an optimized viewing angle of the flame.
WARNING: The top of the fireplace must be installed a minimum of 24" (61 cm) from the ceiling.
The fireplace must be installed a minimum of 5" (13 cm) from the ground.
Installation in a Bathroom
If this unit is installed in a bathroom, it must be protected by a GFCI receptacle or circuit. If a receptacle is used, it
must be readily accessible.
This electrical appliance is NOT watertight. To prevent electric shock, it must be installed as to prevent water from
entering unit, or installed away from showers, tubs, etc. Never locate fireplace where it may fall into a bathtub or
other water container.
Installation Recommendations for
Overhanging Objects
For overhanging temperature-sensitive objects, such
as a television, a mantel, or artwork, always follow the
recommendations provided by its manufacturer for
installation over a heater.
Figure 2 provides the overhang clearance
recommendations for the fireplace. Areas above the
fireplace are marked as follows:
• Solid gray box (
) is subject to temperatures greater
than 65°C (149° F).
• Hatched box (
) is subject to temperatures greater
than 40°C (104° F).
• Clear box (
) is subject to temperatures less than
40°C (104° F).
Figure 2