UNPACKING AND INSTALLING THE MACHINE INSTRUCTIONS FOR USE TROUBLESHOOTING MAINTENANCE PROCEDURE DISPOSAL ORDERING INFORMATION DIMENSIONS HANDLING AND TRANSPORTATION OPERATING HAZARDS PRECAUTIONS WARRANTY INFORMATION DECLARATION OF COMPLIANCE WITH STANDARDS DROPSA LOCATIONS http://www.dropsa.com Manual drawn up in accordance with C2021IE– WK 01/12 EC Directive 06/42...
Dropsa SpA Sales Department should be contacted without delay. DROPSA S.p.A. declines to accept any responsibility for injuries to persons or damage to property in the event of the non-observance of the information presented in this manual.
Page 3
Hydraulic system Connection between the pump and the valve block by steel tubing with connectors. (Only for requested versions) SERIES 999000 ELECTRICALLY MOTOR-DRIVEN PUMP LAY OUT WITH QTY 2 PUMP STANDARD LAY OUT ELEMENTS, BY-PASS, PRESSURE GAUGE, FILLING FILTER, HYDRAULIC INVERTER &...
NLGI 2 5C - + 40 C Temperature of use Consult Engineering Dept For operations outside of this range Dropsa Variable flow rate model: AC Motor 220-380 V 50/60 Hz (specify if single or 3 phase) at 1500 rpm...
Page 5
5.4 Filling filter (only for the grease version) (Accessory) This removable cartridge filter is recommended to ensure the filling of lubricant which is free from foreign bodies and to avoid the formation of air bubbles. 5.5 Hydraulic inverter (Accessory) PART N° DESCRIPTION 86240 Complete with base mounting plate...
7. INSTRUCTIONS FOR USE Verify the settings made; Press the start button of the machine to which the 999 series pump is connected; Verify the starting of the pump; Verify the adequate lubrication of the machine (if doubt exists as to the correct functioning consult the...
8. TROUBLESHOOTING DIAGNOSTIC TABLE ANOMALY CAUSE REMEDY Refill the tank with clean lubricant, in accordance with the The pump does The tank is empty deliver procedure shown in the Maintenance section. lubricant Warning: if the tank has emptied without the minimum level electrical contact having signalled the minimum level, check the contact.
Adjustable Pump Element ANOMALY CAUSE REMEDY Part No. 299041 Ø 6 mm Part No. 299042 Ø 8 mm Irregular flow rate Screw C, which secures Remove pump element the pump element D and assembly from the pump body return spring E, is loose. and completely disassemble it.
In case of doubts and/or problems which cannot be resolved do not attempt to disassemble parts of the machine but contact the Engineering Department of DROPSA S.p.A. 10. DISPOSAL During maintenance or disposal of the machine care should be taken to properly dispose of environmentally sensitive items such as oils or other lubricants.
11.2 Mounting Kit 999 series pumps can be supplied complete with a kit comprising of: Filling filter– Pressure gauge – Pressure regulating valve and mounting Base. To order the Kit it is necessary to indicate the pressure of the pump, the number of pump elements and the number of outlets.
Pump does not produce excessive noise, less than 70 dB(A) . 14.1 LUBRICANTS It is useful to remember that systems manufactured by Dropsa SpA are designed to be used with lubricants with a maximum grade of NLGI 2; Use only compatible lubricants with NBR seals;...
-> the characteristics of the fluid are shown on the pump and in the manual (in case of doubt contact the Eng. Dept of Dropsa Spa) protection against direct and indirect contact must be provided by the user given the purpose of the pump it must always be functioning;...
Dropsa reserves to right to charge an administration fee if the product(s) returned are found to be not defective. This limited warranty does not cover any products, damages or injuries resulting from misuse, neglect, normal expected wear, chemically caused corrosion, improper installation or operation contrary to factory recommendation.
Besana,5 / Dropsa S.p.A. au Siège Social à Milan, Via Besana,5/ Dropsa S.p.A., Sitz in Milano, Via Besana 5/ La sociedad Dropsa S.p.a., con sede legal en Milán, Via Besana,5/ A Dropsa S.p.A, com sede em Milão, via Besana, nº 5 DICHIARA /CERTIFIES / CERTIFIE/ ZERTIFIZIERT, DASS/ DECLARA/ CERTIFICA: che il prodotto denominato/that the product called/ le produit appelè/ das Produkt mit dem Namen/ el producto que se...
Page 15
E-mail: sales@dropsa.it (Export) Fax: (+33) 01 39 86 26 36 E-mail: vendite@dropsa.it (National) E-mail: salesfr@dropsa.com Dropsa (UK) Ltd Dropsa do Brazil Ind. E Com. Ltda Unit 6, Egham Business Village, Rua Sobralia 175, Egham,Surrey,TW20 8RB Sao Paulo, Brazil Tel: (+44) 01784 - 431177...
Need help?
Do you have a question about the 999 Series and is the answer not in the manual?
Questions and answers