Manual compiled in accordance with Directive C2248IE WK 03/17 CE 06/42 http://www.dropsa.com Via Benedetto Croce, 1 Dropsa products can be purchased from Dropsa branches and authorized distributors, visit Vimodrone, MILANO (IT) www.dropsa.com/contact or contact us sales@dropsa.com t. +39 02 250791...
2. GENERAL DESCRIPTION The SUMO II series of lubrication pumps may be adapted to many uses without making any mechanical changes even after it has been installed. In fact, by making a selection from a set of components which are fully compatible and easy to assemble, the pressure, quantity of lubricant delivered, actual type of lubricant or type of distribution can be altered.
N.b. The specifications refer to the temperature of use of +20°C (+68°F) (1) If a different product is used, please contact Dropsa S.p.A. to ensure it is suitable for use. N.B.: do not supply the machine with voltages and pressures different from those indicated on the plate.
5. COMPONENTS STANDARD PUMP COMPONENTS 5.1 FIXED DELIVERY PUMPING ELEMENTS The pump has two fixed delivery standard pumping elements (200 cm^3/ min for each pumping element). The seal between the piston and pumping element casing is dry, as the insertion of a gasket is not required. The pumping element retention valve is of the tapered seal type.
Page 5
ELECTRICAL CONTROL PANEL “DROPSA” electrical control panel has been designed to provide a system complete with all the controls necessary for automatic functioning controlled by safety signals from centralized lubrication installations. The primary voltage is 400 VAC and 50 Hz, the other voltages are on request.
• Use safety gloves or glasses as specified in the safety sheet for the lubricating oil • Do NOT use lubricants which are aggressive towards NBR gaskets, and if in doubt consult the Dropsa SpA technical office which will supply a detailed list of the recommended oils;...
Page 7
[kg] Maximum nsP2 absolute level OUT 2= Fno Minimum level fsP2 Maximum level nsP1 Minimum fsP1 OUT 1= Fno absolute level NOTE: To change calibration thresholds of laser and ultrasound probes contact DROPSA staff 7.3.4 Collegamento galleggiante REED 0295150/0295160...
If you were not able to solve the problem after consulting the diagnostics table, do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the discovered anomalies, with a detailed description.
Pumping elements fixed flow rate 0296080+0295049 1 pumping element with fixed flow rate +3190489- 3190491 * The oil floating level indicate both minimum and maximum level For special versions (e.g. version with separate outlets) contact our DropsA Technical Sales Department.
Page 10
11.2. OPTIONAL Equipment Description Variant P. No. Min/max oil level float kit 30 Kg (66lb) 0295150 Oil conversion Min/max oil level float kit 100 Kg (220lb) 0295160 Filling plug with filter 3130138 Terminal Box bracket Bracket for installing a terminal wiring box onto the base pallet 3044455 Terminal Terminal box...
13. HANDLING AND TRANSPORT A metal pallet is used for transport and storage with packing at the side and a wooden cover. The pump is fixed on a metal pallet, which allows safe handling using a transpallet or forklift truck. The metal pallet has been designed so that it can be installed in the installation, being equipped with 4 (four) holes of Ø...
Lubricants with silicone based additives Petrol – solvents – inflammable liquids Petrol – solvents – inflammable liquids Corrosive products Corrosive products Water Water Food substances Food substances * For more detailed information regarding product compatibility with particular fluids, contact the Dropsa S.p.A. technical office...
Need help?
Do you have a question about the SUMO II Series and is the answer not in the manual?
Questions and answers