Electronic Commercial Water Meter
AquaMaster™
Type
Voltage Rating (V)
Absolute Rating
AC
85 to 265
Battery
3.6 (Lithium)
Pulse and alarm outputs
Three bidirectional solid state switches with common isolation ±35V DC 50mA
Output 1
Forward only, or forward plus reverse pulses
Output 2
Reverse pulses, or direction indicator
Output 3
Alarm indicates any problem with measurement or with power
Pulse output 50Hz maximum, 50% nominal duty cycle
Serial data communications
Local Port
Remote Port (Option)
Telemetry applications using remote serial data communications
External Vodaphone VVADS Radio Pad X25 compatible network interface via RP5, 6, 7 or similar radiopad
External PSTN modem
External GSM modem
Internal GSM modem
Pressure System – External Transducer
Pressure range absolute
10, 16 bar or 300 lb/in2
Connection
Standard quick-fit male probe
MIL style connector
Operating temperature range
–20 to 70°C (–4 to 158°F)
Accuracy (typical)
±0.4% of range
Thermal error band (typically 100°C [212°F])
±1.5% span
Cable length
1, 5, 10 or 20m (3, 16, 32 or 65 ft)
44
Frequency (Hz)
47 to 440
RS232 compatible via ABB lead (Option)
RS232 with RI, RTS and CTS handshaking for connection to a modem or computer
Modern PSTN modems which store configuration setup on non-volatile
memory (for configuration information contact ABB)
Siemens M20T, TC35 or similar compatible modems
(for configuration information contact ABB)
Dual Band GSM; fully programmable schedule for battery operation and
Automated Meter Reading. Logged data transmission via SMS Text.
VA
<10
5 Specification
IM/AM
Issue 13