ABB AquaMaster Instruction Manual page 24

Electronic commercial water meter
Hide thumbs Also See for AquaMaster:
Table of Contents

Advertisement

Electronic Commercial Water Meter
AquaMaster™
Fig. 3.13 Transmitter Connections (Glands/Conduit Entry)
Caution. (Remote versions)
Remove foil screens completely, and plastic/foil screens and any fillers
Twist the three screen wires together and sleeve them.
Keep cable pairs twisted.
Make connections only as shown.
Maintain Environmental Protection at all times.
Conduit connections must provide cable entry sealing.
1
Fig. 3.14 Sensor Cable Connections (Gland/Conduit, Remote version)
Caution. With Belden Cable 8777, ensure that the black wires are not interchanged and remain with the
associated twisted pair.
22
7
3 Electrical Installation
CABLE
ABB
1 Brown(BN)
2 Red (RD)
3 Orange (OR)
4 Yellow (YL)
5 Sleeved Ground
6 Blue (BL)
7 Violet (VI)
Belden 8777
1 Black
2 Green
3 Black
4 Red
5 Sleeved Ground
6 Black
7 White
IM/AM