Electronic Commercial Water Meter
AquaMaster™
Temperature Ranges
Process
70°C (158°F)
–10°C (14°F)
Note. Operation outside ambient temperature limits of 0 to 50°C (32 to 122°F) reduces battery capacity and
shortens battery life.
Pressure Loss
Flowrate
Q3 (CEN)
ISO 4064 Q
.
max
ISO 4064 Q
n
ISO 4064 Q
n/2
Transmitter
Mounting
Integral with sensor
or
Remote up to 200m (650 ft)
Housing
IP68 (NEMA 6P) Aluminum Alloy with Glass Window
Electrical connections
20/16mm plastic glands, 20mm armored or accepts
Sensor cable
ABB cable supplied as standard
SWA cable available on application
Power supply
Battery life @ 0 to 50°C (32 to 122°F)
1 battery – typically 1.2 years
2 batteries – typically 3 years, extended life is possible to give, say, 5 years for two cells with a small degradation in
response time and slightly increased measurement uncertainty, contact ABB for details.
Battery life is shorter with GSM, depending on how frequently it is used and for what period. For example, used once
per day for SMS automated reporting of data logged at 15 minute intervals, the total life of 2 batteries would be typically
reduced to approximately 2 years.
IM/AM
Issue 13
Ambient
–10°C (14°F)
Pressure Loss (Bar)
< 0.63
< 0.3
< 0.075
< .019
1
/
60°C (140°F)
–20°C (–4°F)
in. NPT threaded or military style plug & socket
2
5 Specification
Storage
70°C (158°F)
–30°C (–22°F)
43