Intec CA10 Instruction Manual page 7

Hide thumbs Also See for CA10:
Table of Contents

Advertisement

Use a hacksaw and cut approximately 10 inches out of the pipe after the filter
Please note – this measurement can be different as bushings vary in depth. Take the male
half of each union that contains the reducer/bushing, clean the inside and cement
assembly component on the remaining pipe ends (Figure 5). Slide in the electrode and
hand tighten the female union to the male union.
Male
Union
2" Plumbing
Use a hacksaw and cut approximately 9.5 inches out of the pipe after the filter
The electrode can be installed horizontally or vertically. Take the male half of each union
and clean and cement them on the remaining pipe ends. Slide in the electrode and hand
tighten the female union to the male union.
Connecting the Electronics Unit to the Electrode
Locate the male spades found at each side of the electrode (Figure 6). Connect the
female plug located at the end of the wire from the electronics unit and connect it to the
male spade located on the electrode (Figure 7). Attach the unconnected wire for the
electronics unit to the other side of the electrode (Figure 8). It does not matter which wire
plugs into which side of the electrode. The polarity will alternate the current between the
two copper bars on the electrode. Figure 9 illustrates the proper connection for the
electronics unit to the electrode.
Bushing
Reducer
Figure 4
7
Assembly
Component
Female
Union
Figure 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cv50Cv60

Table of Contents