CV60 Operator Interface
Display
The CV60 has a two digit seven-segment LED display. The segments are driven direct so
a limited set of alpha characters can be displayed in addition to numbers.
The following is a list of displayed variables on the CV60:
1. Setpoint Amps – 00 to 20
2. Cell Amps – 0.0 to 2.0 (accuracy of +- 0.1 amps)
3. Cell Volts – 1 to 24
4. Control Status & Alerts
a. A0 – Normal operation
b. E1 – Flow switch open (no water flow)
c. E2 – Cell connection problem or low TDS indication (cell is powered with
no feedback). See notes page 19
d. E3 – Output reduced because of internal heating. Too high TDS in water,
too high of a setpoint, or combination of both.
5. Power-up Mode
a. P1 – Powers up off
b. P2 – Powers up on (default as shipped)
The display variables can be changed by pressing the "SEL" pushbutton and indicated by
the LED Light to the left. Options are SETPOINT, CURRENT, VOLTAGE. The
SETPOINT is the default and one can increase/decrease the rate of copper production by
simply pressing the "UP" or "DOWN arrows to increase or decrease the copper ion
output while the LED is next to the SETPOINT indicator.
Current and Voltage
One can also change the power output by pressing the "SEL" pushbutton until the LED
indicator is located next to the SETPOINT. Use the "UP" or "DOWN arrows to change
the copper output. To view the output, press the "SEL" pushbutton until the indicator is
next to CURRENT (amperage) or VOLTAGE (direct current volts). The CURRENT is a
better indicator of the rate copper will ionize. It is best to keep this under 1.7 to prevent
overheating or accelerated copper depletion. The combination of these two items is more