2.
CA10 AND CV50 INSTALLATION OVERVIEW
The copper electrode is the only part of the system that must be installed. It is installed
after the pool filter and before the pool heater (if you have a heater).
Figure 1
Figure 2. CA10 and CV50 Electrode
Figure 3. CV60 Electrode
Installation of the Electrode
1.5" Plumbing
You will need to use a 2" to 1.5" reducer bushing (not provided). The electrode
can be installed horizontally or vertically. Take the male half of each male union, clean
them both, and then cement the bushing/reducer into the male union (Figure 4).
6