useful to a technician for troubleshooting and it is suggested to just use the setpoint
screen.
Manual Power On/Off or Automatic One
The CV60 is shipped standard where one must manually turn the system on. This is best
utilized when the system is plugged into a standard outlet, wired into a timer, or utilizing
the flow switch. To power up, simply press the "ON" button. To turn the system off,
simply press the "OFF" button. If being used with a flow switch or the system is wired
into the pump or timer, then you want power applied to it whenever the pump is running
which is the default Program P2. For those that only want to run the system when
needed and manually control the addition of copper (usually one a week), one needs to
change the program to Program P1.
Changing the Power-up Mode
To change this setting the system must be plugged in and manually press the "OFF"
button. With the unit now powered off, unplug the CV60 from the incoming power
supply. Press and hold the "DOWN ARROW" while plugging the power cord back into
the power outlet. A "P1 or P2 code will be displayed. Please see above for the selection
preference. Push the "SEL" push button to lock this program in and return to the home
screen.
The Power-up Mode will be displayed when the
pushbutton is pressed and held down when AC power is being applied.
Setpoint Select
The copper ion release rate on the CV60 is adjusted using scroll up and scroll down panel
pushbuttons when the LED indicator is next the "Setpoint". The controller will maintain
the last used setpoint value during power down or when power is reapplied to the system.
Power On & Off
Power on and off on the CV60 may be selected via ON and OFF panel pushbuttons.
rather than a power toggle switch found on the CA10 and CV50.
Alert LED
The ALERT LED will illuminate if any of the E1 to E3 conditions described earlier are
present.