(2) Starting and Finishing the BLG-TestProgram
Starting the BLG-TestProgram
1. Mount a checking lens to the lens mount block.
2. Connect the D-sub 15-pin cable to the lens mount block, and
turn on the B-L Control Box.
3. Start "BLG-TestProgramV[][][].exe".
4. Click [Open] to connect communication with the B-L Control
Box.
Note: When the B-L Control Box or personal computer to be used
is started for the fi rst time, a password must be entered.
Enter a password and click [OK], then proceed to step 5.
Connection to the lens mount block is established and the
[Power] button is made active.
When the password input window opens, ask service head-
quarters about password. In this case, the ID shown in
"COM/USER Characteristic Number" must be informed
("YdDGAAHTJ" in the example above).
Since this ID number is unique to the B-L Control Box and
personal computer, if used another B-L Control Box or per-
sonal computer, another password is necessary.
5. Connection to the lens mount block is established and the [Power]
button is made active.
Procedure of Finishing
1. Click [Power] to turn off the power to the lens.
2. Confirm that the two LEDs on the B-L Control Box are not lit.
3. Click [Close] to disconnect communication between personal
computer and B-L Control Box.
4. Click [Finish] to exit the program.
5. Turn OFF the lamp switch of the Lens Test Projector.
6. When the Lens Test Projector is cooled down after several min-
utes, turn OFF the main switch of the Lens Test Projector.