Adjusting the Operating Lever

The Accu-Shot valve operating lever (36) can be
adjusted using the adjustment set screw (41) and check
nut (40). See Fig. 7. The Accu-Shot is shipped with the
lever already locked and set and therefore does not nor-
mally require adjustment. It may need adjusting after
being used for some time or when the valve is removed.
1. Loosen the check nut (40). See Fig. 7.
2. Tighten or loosen the set screw (41) until the
required position is reached.
3. Fully lock the check nut (40), keeping the set screw
(41) in position.
NOTE: when the adjustment set screw is loosened, the
operating lever rest position (valve closed) moves away
from the grip. Once adjustment has been performed the
position of the lever with respect to the grip must be as
illustrated in the Overall Dimensions. See page 14.
40
41
Fig. 7
10

Cleaning the Valve

1. Loosen the nut (40) and remove it together with the
2. Unscrew the battery cap (34) and remove the two
3. Unscrew the 4 fastening screws (23) and remove
4. Remove the screws (21) along with the electronics
NOTE: handle the card and all card componets very
carefully.
NOTE: before beginning step 5, obtain a container to
hold the disassembled internal components of the valve.
5. Unscrew and remove the valve plug (16).
36
set screw (41). See Fig. 7.
batteries (28). See Fig. 5.
the outlet housing (24), the plate (25), and the plate
gasket (26). See Fig. 8.
(17).
17
21
26
25
24
23
Fig. 8
Service
8
12
10
14
9
11
13
15
16
TI1670A
22
309454C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accu-shot 233933

Table of Contents