Troubleshooting - Oneida Air Systems AXD002030AXL Manual

Super dust deputy 6" xl cyclone
Table of Contents

Advertisement

Troubleshooting

PROBLEM
Not separating well.
(Only a tiny amount of
dust should reach the
collector).
Material swirls in
Cyclone and won't drop
into the dust container.
Material swirls in
Cyclone and won't drop
into the dust container.
Low Air Volume
Drum Collapsing
C AUSE
Air leaks in the drum
Collecting large bulky
material
System clogged
Blocked airflow
SOLUTION
1. Make sure the lid of the dust drum is in place and well seated.
2. Check for any damage to the foam seal of the lid.
3. Ensure the drum lid clamp is tight.
4. Check for holes or leaks in the dust drum.
5. Check for leaks along the flange of the cyclone.
6. Check for leaks on the outlet's shoulder connection.
1. Large, bulkier material might swirl. Restart or temporarily cut
off air flow to drop material down.
1. Clean collector's filter per the manufacturer's specs.
2. Check all hose connections for a blockage in the hose.
1. Ensure at least one gate is open during operation of your dust
collector.