Specifications - Honeywell GA-SP01 User Manual

Motorized sampling pump
Table of Contents

Advertisement

The Sampler
Users Manual

Specifications

Operating Humidity: 5% to 95% relative humidity
(non-condensing)
Sample Flow Rate: Typical 300 ml/min
Sample Distance: 50ft/15.2m maximum recommended.
Sample Delay Time: 3 seconds per 1ft./0.3m.
Connections: Outlet 1/8 in. (3.175 mm) barbed fitting for
soft hose.
Inlet 1/8 in. (3.175 mm) barbed fitting for soft
hose or 1/4 in. (6.35 mm) O.D. for rigid tube.
Weight: 6.2 oz./175 g
Dimensions
7.4 x 1.3 x 2.1 in./18.8 x 3.35 x 5.4 cm
:
Visual Alarm: Three high-intensity LEDs
Warning Conditions: Low flow, low battery, system fault
Typical Battery Life: Alkaline, NiMH 30 hours
(at +25
Altitude: Up to 9843 ft./3000 m
Pollution Degree: 2
Installation Category: I
Approved Batteries:
North America
Alkaline:
Duracell MN1500
Energizer E91
NiMH rechargeable:
Quest Platinum HGAAC1800G
Quest HG1600AACS
Energizer NH15
22
o
o
C/77
F)
Temperature Code
150°C
163°C
211.4°C
199°C
205°C
Shop for BW products online at:
Maha Powerex 1700 mAh MH-AA170
Maha Powerex 1800 mAh MH-AA180
Yuasa Delta 1300 mAh DHA1400AA
Yuasa Delta 1500 mAh DHA1600AAC
Worst Case Temperature Code:
Alkaline
NiMH
Ambient
Europe
Alkaline:
Duracell MN1500
NiMH rechargeable:
Quest HG1600AACS
Worst Case Temperature Code:
Alkaline
NiMH
Ambient
Battery Charger (optional): Quest™ Q2 4-port rapid NiMH
battery charger with country-specific mains adapter
Charge Time: 1-3 hours
Approvals: Approved by CSA to both U.S. and Canadian
Standards.
Class I, Division 1, Group A, B, C, and D;
Class I, Zone 0, Group IIC
ATEX: CE 0539 g II 2 G KEMA 03ATEX1500
EX Approval: EEx ia IIC
X: European Conformity
ABS Type Approved VA-348-169-X
optimumstores
www.
.com/bw
192°C
201.1°C
209°C
204.4°C
163°C
212°C
-20°C≤Ta≤+50°C
Temperature Code
T4
T3
129.8°C
189°C
-20°C≤Ta≤+40°C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga-sp02

Table of Contents