Honeywell GAMIC-V-CHRG1 User Manual

The sampler motorized sampling pump

Advertisement

Quick Links

The Sampler
Motorized Sampling Pump
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell GAMIC-V-CHRG1

  • Page 1 The Sampler Motorized Sampling Pump User Manual...
  • Page 3: Table Of Contents

    The Sampler User Manual Table of Contents Contacting BW Technologies by Honeywell ........0 Deactivating the Sampler ..............6 Copyright, Notices, Trademarks............1 Alarms....................6 Signal Words ..................1 Low Flow Alarm......................6 Low Battery Alarm ......................6 International Symbols................1 System Fault Alarm ...................... 6 Introduction ...................1...
  • Page 5: Contacting Bw Technologies By Honeywell

    If any provision of this warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Contacting BW Technologies by Honeywell Corporate Headquarters...
  • Page 6: Copyright, Notices, Trademarks

    International Inc. (Honeywell) is prohibited except as authorized in writing. This unpublished work is protected by the laws of the United States and other countries. While this information is presented in good faith and believed to be accurate, BW Technologies and/or Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers.
  • Page 7: Introduction

    The Motorized Sampling Pump (the Sampler) is a spot sampling device that can be used with most BW Technologies by Honeywell (BW Technologies) single and multiple gas detectors. An internal motorized pump transports potentially hazardous gases from a sample area to a detector.
  • Page 8: Safety Information - Read First

    To avoid personal injury: • Replace the batteries as soon as the Sampler indicates a Low Battery Alarm. • Use only batteries recommended by BW Technologies by Honeywell to prevent • This instrument contains batteries. Do not mix with the solid waste stream.
  • Page 9 The Sampler Safety Information - Read First Pushbutton Action Description Activate Press C to activate. Short sample tube (inlet) Press C and hold for 2 seconds to deactivate. The Deactivate Sampler beeps, then deactivates. The Sampler Activation button enters calibration mode the next time it is activated. •...
  • Page 10: Getting Started

    What’s in the Box The list below provides the standard items included with the Sampler. If the Sampler is damaged or parts are missing, contact BW Technologies by Honeywell or an authorized distributor immediately. • Batteries (2 replaceable AA alkaline cells) •...
  • Page 11: Standard Hose Configuration

    The Sampler Operating Guidelines Standard Hose Configuration Sample Tube Connections The Sampler is shipped with the short sample tube installed. To remove the installed sample tube, grasp the end of the tube and pull straight out. Insert the new sample tube through the enclosure and into the gasket opening. To ensure a proper seal, the end of the tubing should be inserted until firm resistance is felt.
  • Page 12: Deactivating The Sampler

    The Sampler User Manual Deactivating the Sampler Calibration To deactivate the Sampler, press C and hold for 2 seconds. Upon startup, the audible alarm emits three beeps, the pump activates at a high speed and the green ON LED flashes. The audible alarm beeps 3 times, all LEDs light up and then the Sampler turns off.
  • Page 13: Maintenance

    To avoid personal injury: • Replace the batteries as soon as the Sampler indicates a Low Battery Alarm. • Use only batteries recommended by BW Technologies by Honeywell to prevent damage or personal injury and maintain intrinsic safety. #4-40 x 3/8 in button Batteries •...
  • Page 14: Replacing A Filter

    The Sampler User Manual Replacing a Filter Draining the Water Trap The filter must be changed when it becomes clogged with dirt. Empty the water trap periodically. Remove the filter plug assembly from the Sampler. Pull open the drain plug and shake any water out of the water trap. Replace the plug when complete.
  • Page 15: Troubleshooting

    Depleted batteries. Replace batteries. Damaged or defective Sampler. Contact BW Technologies by Honeywell or an authorized distributor. Continuous low flow alarm. Extreme environmental change has formed condensation in the Wait approximately 15 minutes for the condensation in the Sampler to clear.
  • Page 16: Replacement Parts And Accessories

    Model No. Description Qty. Dimensions: 7.4 x 1.3 x 2.1 in/18.8 x 3.3 x 5.3 cm GAMIC-V-CHRG1 12V vehicle charger and 4 AA NiMH batteries Visual Alarm: Three high-intensity LEDs GAMIC-C01-K 110 VAC 4-port charger and 4 AA NiMH batteries...
  • Page 17 The Sampler Specifications Battery Charger (optional): Quest™ Q2 4-port rapid NiMH battery charger with country-specific mains adapter Charge Time: 1-3 hours Approvals: Approved by CSA to both U.S. and Canadian Standards. Class I, Division 1, Group A, B, C, and D; Class I, Zone 0, Group IIC IECEx Approval: Ex ia IIC Ga IECEx CSA04.0003X...
  • Page 18 The Sampler User Manual...
  • Page 20 50105442-056, Rev 3 English © BW Technologies 2013. All rights reserved.