Product Specifications; Electrical Specifications; Operating Temperature; Protection Level - ZLG CANFDNET-200U User Manual

High-performance dual-channel ethernet to can (fd) converter
Table of Contents

Advertisement

CANFDNET-200U
High-Performance Dual-Channel Ethernet to CAN (FD) Converter User Manual

2. Product Specifications

2.1 Electrical Specifications

Item
Working voltage
Power consumption

2.2 Operating Temperature

2.3 Protection Level

Interface
Power supply
CAN bus
Ethernet
Buttons, Indicators
Table 2.4 Protection level-electrical fast transient pulse group immunity test (IEC61000-4-4)
Interface
Power supply
CAN bus
Ethernet
Interface
Power supply
CAN bus
Ethernet
Table 2.1 Electrical specifications
Conditions
DC
Table 2.2 Operating temperature
Item
Operating temperature
Storage Temperature
Table 2.3 Protection level-electrostatic discharge immunity test (IEC61000-4-2)
Test Level
Level 4
Level 4
Level 4
Level 4
Test level
Level 3
Level 3
Level 3
Table 2.5 Protection level-surge (impact) test (IEC61000-4-5)
Test Level
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
Minimum
9
-
Rating
Minimum
Typical Value
-40
-
-40
-
Test Voltage (kV)
Test Result
6
6
6
8
Test voltage (kV)
Test Result
2
2
2
Test Voltage (kV)
1
1
1
1
1
1
3
Rating
Typical Value
12
1.5
Unit
Maximum
85
85
Remarks
Class A
Contact discharge
Class A
Contact discharge
Class A
Contact discharge
Class A
Air discharge
Remarks
Class A
Capacitive coupling
Class A
Capacitive coupling
Class A
Capacitive coupling
Test Result
Remarks
Class A
Line-line
Class A
Line-ground
Class A
Line-line
Class A
Line-ground
Class A
Line-line
Class A
Line-ground
©2021 Guangzhou ZLG Electronics Co., Ltd.
User Manual
Unit
Maximum
48
V
-
W

Advertisement

Table of Contents
loading

Table of Contents