Technical Data; Subsea Canister Aluminum; Subsea Canister Titanium Rev. 1 - Innova MATRIX MK II+ Operation And Maintenance Manual

Table of Contents

Advertisement

Innova – Matrix MK II+
Operation and Maintenance Manual
Project No.:
5.2

Technical data

5.2.1 Subsea Canister Aluminum

Dimensions:
Depth rating:
Supply voltage:
Maximum power consumption:
Minimum power consumption:
Recommended fuse:
Maximum inrush current:
Housing material:
Weight in air:
Weight in water:

5.2.2 Subsea Canister titanium rev. 1

Dimensions:
Depth rating:
Supply voltage:
Maximum power consumption:
Minimum power consumption:
Recommended fuse:
Maximum inrush current:
Housing material:
Weight in air:
Weight in water:
P.O. BOX 390
4067 Stavanger, Norway
Document No.:
604653
L = 600 mm, Ø = 220 mm (Ø = 210mm in centre)
3000 m
85-260VAC, 50-60Hz
120-370VDC
1200W
150W
16A (@110VAC)
40A (@265V
Aluminium 6082-T6, hard anodized
35 kg
13 kg
L = 600 mm, Ø = 220 mm (Ø = 210mm in centre)
3000 m
85-260VAC, 50-60Hz
120-370VDC
1200W
150W
16A (@110VAC)
40A (@265V
Titanium grade 5
50 kg
28 kg
Tel.: +47 51 96 17 00
Fax.: +47 51 96 17 01
MAN-000015294
Cold start)
RMS,
Cold start)
RMS,
Date
12.12.2017
Page
24 of 74
Rev.
5
post@innova.no
www.innova.no