Enable Supervision Of Wireless Zones; Rf Jam Detect Zone - DSC RF5501-433 Installation Manual

Table of Contents

Advertisement

O
T
H
If the PC5132 portion of the RF5501-433 module does not show on the keypad, one of
the following conditions may be present:
• the module is not connected properly to the Keybus
• there is a problem with the Keybus wiring run
• the module does not have enough power
• no devices have been enrolled on the RF5501-433

4.3 Enable Supervision of Wireless Zones

NOTE(for PC5010 v1.x control panels only): For UL Listed installation, Double EOL
resistors must be enabled in the PC5010 for the wireless zones to be supervised. If
normally Closed or Single EOL resistors are selected the PC5010 will not be able to
supervise the wireless devices. If a wireless device stops sending a supervisory signal
(the unit stops functioning) the panel will not indicate a supervisory trouble condition
unless Double EOL resistors are used. In addition, all hardwire zones must be wired for
Double EOL resistors. For more information, refer to your PC5010 v1.x Installation Manual.
NOTE: (PC5010 v2.0 and higher, PC5015 v2.2 and higher, PC5020, PC5008, PC1555/
1565, PC580/585 only): For wireless supervision to work, you must enable the wireless
zone attribute on all wireless zones (sections [101] to [132], option [8] ON).
NOTE: The RF Jam Detect zone must have the supervision option disabled.
Wireless Supervisory Window
Each wireless zone will send a supervisory signal every 64 minutes. If the receiver does not
receive a signal within the time programmed for the Wireless Supervisory Window, it will
generate a supervisory fault.
To program the wireless supervisory window:
1. Enter [✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter into Receiver Programming.
3. Enter sections [81].
4. Enter the time period for the supervisory window. The window is programmed in 15
minute increments. The default programming is 96 (x15minutes), which is equal to
24 hours. Valid entries are (16) - (96), equal to 4 - 24 hours.
5. To exit press [#].
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by default. To disable supervision for any
zone, enter the following at any system keypad:
1. Enter [✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the RF5501 Module Programming.
3. Enter sections 82-85. Enable and disable zone supervision by turning on/off the
corresponding zone toggle option.
4. To exit press [#].
4.4 Jamming Signal Detection
The RF5501-433 receiver detects jamming signals that can prevent the receiver from
properly receiving transmissions from enrolled devices. When jamming signals are
detected, the panel can report a jamming trouble condition in one of two ways. By default,
the panel will report an RF Jam Trouble (General System Tamper on the PC5010).