K
E
Y
P
[6]
ON =
Door Chime Enabled for Zone Openings
OFF = Door Chime Disabled for Zone Openings
[7]
ON =
Door Chime Enabled for Zone Closings
OFF = Door Chime Disabled for Zone Closings
5. When you are finished, press [#] to exit.
Door Chime Sounds
You can program the RF5501-433 keypad to make different door chime sounds for
individual zones, or groups of zones. Each RF5501-433 keypad can make any of four
door chime sounds for each zone that triggers the door chime:
• 4 quick beeps (default sound)
• 'Bing – Bing' tone
• 'Ding – Dong' tone
• 'Alarm' tone
NOTE: For a zone to be able to trigger the door chime sound, the Door Chime zone
attribute must also be enabled in the control panel programming. Please see your control
panel Installation Manual.
To change the door chime sounds:
1. Enter [*][8][Installer Code].
2. Enter [*] to go to door chime sound programming.
3. Enter a 2-digit number for the zone you want to program [01] - [32].
4. Turn one of the following options on by pressing [1], [2], [3], or [4]:
[1]
4 quick beeps (default sound)
[2]
'Bing – Bing' tone
[3]
'Ding – Dong' tone
[4]
'Alarm' tone
NOTE: Ensure that only one of the above options is turned on. If more than one is on,
the keypad will sound the first option that is enabled. If none of the options are selected,
the keypad will not make any sound when the zone is opened or closed.
5. To program the door chime sound for another zone, repeat steps 3 and 4.
6. When you are finished programming the door chime sounds, press [#] to exit.

2.7 Low Temperature Alert

The RF5501-433 keypad is capable of detecting a low temperature environment.
Once enabled and the zone input disabled (see section [90]), the keypad will report
an alarm condition. If the environment becomes less than 6
o
greater than 8
C, the zone will restore depending on zone type and panel status.
[Installer Code]
Enter [*][8]
Enter [000]
Enter Section [7]
Press [8] to enable/disable temperature sensor
[8] ON = Low Temperature Alert enabled
OFF = Low Temperature Alert disabled