Download Print this page

Cello Vetlanda 502256881 Instruction Manual page 2

Advertisement

GB
Important information
Please check the construction set for completeness
using the position list in good time before starting
construction or commissioning your construction
team. If individual parts are defective or missing, we will
deliver these as quickly as possible. However, we cannot
refund the costs for any resulting construction delays to a
construction company.
Please understand that we cannot assume any
guarantee for the following defects:
- incorrect storage before assembly
- incorrect anchoring with the ground or inadequate
foundation (foundation according to statics)
- damage due to erection errors, e. g. the house is not
level or not right-angled
- damage through a higher level of snow burden than
statically envisaged. Recommendation: lad relief of the
roof by removing the snow layer
- storm damage (insurance cases) or violent destruction
- damage through any alteration to the design by the
client
- natural formation of cracks, branch holes, twisting,
decolouration or similar modification (natural process;
has no influence on the statics)
Storage information until construction:
- Store pallet on a level and dry surface.
- Protect from exposure to sunlight and the influences of
weather; wood can warp drastically in a loose
condition!
Maintenance tips:
The wood is untreated.
Accordingly, regular, protective coating
is absolutely necessary! Please observe
the attached information sheet "Care
instructions/Colour treatment"
General tips and refers to:
The packaging foil can be used to keep
1
moisture out of the house. It is laid according
to the ground area of the house under the
main bearing.
2
If a felt is used as a roof cover, we recommend
two layers. Underlay on the bottom and a
surface layer on the top.
3
A possibly desired installation of a rain gutter
must be done by the building contractor; for
this the roofing boards must be cut to the right
length.
Foundation according to the structural
1
calculations (not included in the scope of
delivery): concrete C25/30, each 2 Ø 12 top
and bottom, brace mat R188A (alternatively
brace Ø 6/20cm). Anchoring of the floor
beams (in the building) on the strip foundation
using bolts M12, e < 60cm. The base bearings
in the storeroom of the house must be entirely
flush.
2
The wooden parts of the building kit are
delivered with a residual moisture content
of about 15%. Wood "works"! This means
that the wooden parts will swell during
prolonged damp weather and shrink (dry
out) during prolonged dry periods. This only
occurs in height or width, not lengthwise.
The block planks are firmly screwed to the
vertical corner post during installation. This
will not change its length, but the horizontally
attached planks change their height. If damp
weather persists, the block planks can swell
slightly after completion. It is therefore
important to leave 1mm clearance between
the planks when fitting. Use the enclosed
spacer (to avoid unnecessary strains in the
structure).
If the door cannot be closed properly, this can
3
be adjusted by turning the hinges.
2
Technical modifications reserved.
All dimensions are approximate dimensions.
Date 12/20