Id-No. 00.95770.100000 – Alstom-Id-No. DTR0000532873
Technical like Ser[LOG]. Differences:
Communication interfaces:
Analog/Digital inputs:
Resolution:
Measurement data processing: 8-byte IEEE real format
Outputs Sensor supply:
Dimensions/ Weight:
AnDiMod - expansion module analog/digital inputs
AnDiMod - Address 1 Article No. 00.95770.200000
AnDiMod - Address 2 Article No. 00.95770.200001
AnDiMod - Address 3 Article-No. 00.95770.200002
Extends the analog and digital inputs of Ser[LOG] and Ser[LOG]Plus (observe order!).
Communication interfaces:
Analog/Digital inputs:
Ser[LOG] extension:
Ser[LOG]Plus extension:
Ser[LOG] and Ser[LOG]Plus are max. expandable to: 36 analog / 11 digital inputs
Resolution:
Measurement data processing: 8-byte IEEE real format
Power supply:
Outputs sensor supply:
EMV:
Mounting bracket:
Dimensions/ Weight:
Housing:
LAMBRECHT meteo GmbH
4 x RS 485 · 5 x RS 422 · 4 x RS 232 · USB device · USB host ·
Ethernet
2 analog / 5 digital inputs
16-bit ADC (SAR) with up to 1024x oversampling
6x V0 (10... 30 VDC) · max. current output via all: 500mA
135 x 238 x 72 mm · approx. 1.3 kg
Ser[LOG]-Bus (RS485)
12 analog / 3 digital inputs
up to 3 AnDiMod
up to 2 AnDiMod
16-bit ADC (SAR) with up to 1024x oversampling
via Ser[LOG] or Ser[LOG]Plus 10...30 VDC
6x V0 (10...30 VDC) · max. current output via all: 500 mA
IEC 60945
for 35 mm DIN rail
135 x 114 x 72 mm · approx. 0.6 kg