Operating Instructions Data logger TROPOS (95666) TROPOS-124 TROPOS-112 Contents 1 Introduction TROPOS-100 2 Functional description 3 Components and scope of delivery 4 Commissioning of TROPOS 4.1 Confi guration of TROPOS 4.2 Operation via push-/ rotary switch 4.3 The menu items 4.4 Wiring of the TROPOS ports...
• TROPOS is available in 3 different versions: skipped. 1. TROPOS-100 · to connect one precipitation sensor 2. TROPOS-112 · to connect up to 1+12 sensors 3. TROPOS-124 · to connect up to 1+24 sensors Data processing Push-/ rotary Data acquisition •...
Page 3
Operating Instructions Data logger TROPOS (95666) 4. Now all necessary wiring activities at TROPOS have to be TROPOS has to be connected to a COM interface of carried out, without the connection of the power supply, that your PC by means of the delivered connecting cable + is without putting the plug into the socket.
Operating Instructions Data logger TROPOS (95666) Operation via push- / rotary switch Time Time The time is adjustable in the 1. When TROPOS is connected to the supply voltage (after 20:58:00 format hh:mm:ss, similarly to the finish of all wiring operations), TROPOS V 1.xx adjustment of the date.
Operating Instructions Data logger TROPOS (95666) In one of two possibilities the card must be inserted easily. 1) Connection of the power supply • The “+” pole from a DC power supply unit After insertion of the CF card this indica- Change CF has to be connected to (V+) port.
Page 6
Operating Instructions Data logger TROPOS (95666) 5) Connection of the digital input - reed contact for a 7) A1...A6 Measurement of current precipitation sensor • The currents are measured ground referred („single-end- • A voltage of +5 V is permanently applied on the input ed“).
Page 7
Operating Instructions Data logger TROPOS (95666) 9) A1...A6 Measurement of voltages over +5 V 10) D1...D4 Digital measurements of frequencies, pulses or status • The voltages up to +5 V can be measured directly. • The voltages over +5 V can also be measured, e. g. meas- •...
Please note: the PC and the accordance of the baud rates. Use only CF cards which are released by LAMBRECHT - with • By click on the button ID? : Checking of the accordance extended operating temperature range, industrial standard!
Page 9
Operating Instructions Data logger TROPOS (95666) D4...Status: D1...D3: 4 outputs 1 digital input 3 digital inputs sensor power supply, Counter, frequencies up to 4 kHz 3 of them switchable via software A7...A8: 2 analogue inputs: • ± 50 mV Processing module Acquisition module Power supply input 10...24 V...
Operating Instructions Data logger TROPOS (95666) TROPOS in the housing (examples) TROPOS Module Depending on order content and purpose the following mod- Example 1: TROPOS-112 with mains voltage (unwired) ules can be connected to TROPOS: Id-No. Basis module “power supply” TROPOS-PS/1 32.95666.040 010 Power supply standard (weight ~300 g)
• Wind statistics thorized manipulation of the system. You need a written • Data transfer as Windows System Service permission of the LAMBRECHT meteo GmbH for changes of system components. These activities must be operated Accessories by a qualifi ed technician.
Page 12
Data evaluation: PC evaluation software „MeteoWare ...“ (option) Data format: LAMBRECHT proprietary, suitable for ASCII export and Excel compatible Quality System certified by DQS according to DIN EN ISO 9001:2008 Reg. No. 003748 QM08 Subject to change without notice.