Lambrecht Ser[LOG] Operator's Manual page 113

Hide thumbs Also See for Ser[LOG]:
Table of Contents

Advertisement

E_08121.100002_P_4-20mA_600-1100
E_08121.100002_P_4-20mA_800-1100
E_08128.XXXXXX_P_0-5V_600-1060
E_08128.XXXXXX_P_0-5V_800-1060
E_08128.XXXXXX_P_0-5V_600-1100
E_08128.XXXXXX_P_0-5V_800-1100
E_08241.000000_Temp_PT100_-30-70
E_08280.008503_Temp_PT100_-40-70
E_08281.008005_Temp_PT100_-30-70
E_08411.000000_soil moisture0-1V
E_14512.XX0030_WD_F1000
E_14521.100040_WD_Prof._4-20mA
E_14522.100040_WS_Pro_4-20_75m/s
E_14523.130040_WD_PRO_WEA
E_14523.230040_WD_PRO_WEA/RF
E_14524.100040_WS_PRO_WEA
D_14524.200040_WG_PRO_WEA/RF
E_14565.200304_WD_ECO_4-20
E_14566.000030_WD_Met_F1000
E_14566.200304_WD_Met_0-20mA
E_14566.200304_WD_Met_4-20mA
E_14567.X00000_WD_Ind_0-20mA
E_14567.X00040_WD_Ind_4-20mA
E_14575.200004_WS_0-20_35m/s
E_14575.200004_WS_ECO_4-20_35m
E_14576.250004_WS_Met_0-20_50m/s
E_14576.250004_WS_Met_4-20_50m/s
E_14577.X00000_WS_Ind_0-20_50m/s
E_14577.X00040_WS_Ind_4-20_50m/s
E_15235.100000_Evapor.__5V_200mm
E_16103.000000_Radiation
E_16110.X00000_RB
E_16123.000000_RB
E_16130.X00000_Radiation
E_16131.X00000_Radiation
D_16321.010342_Helligkeit_4-20mA
LAMBRECHT meteo GmbH
Air pressure sensor 00.08121.100002 configured to
4...20 mA = 600...1100 hPa
Air pressure sensor 00.08121.100002 configured to
4...20 mA = 800...1100 hPa
Air pressure sensor of the series 8128 with 0...5 V = 600...1060hPa
Air pressure sensor of the series 8128 with 0...5 V = 800...1060hPa
Air pressure sensor of the series 8128 with 0...5 V = 600...1100hPa
Air pressure sensor of the series 8128 with 0...5 V = 800...1100hPa
Grade temperature sensor Pt100 in the measuring
range -30...+70 °C
Ground/ Water/ Temperature sensor Pt100 in the measuring
range -30...+70 °C
Air temperature sensor Pt100 in the measuring range -30...+70 °C
Soil moisture sensor 8411 (TRIME) with
0...1 V = 0...100 % water content
Wind direction of the combined wind sensor 14512 with potentiome-
ter (1000 Ω).
Wind direction sensor of the PROFESSIONAL series with
4...20 mA = 0...360°
Wind speed sensor of the PROFESSIONAL series with
4...20 mA = 0...75 m/s
Wind direction sensor of the PRO-WEA series with
4...20 mA = 0...360°
Wind direction sensor of the PRO-WEA series with RF wind vane
and 4...20 mA = 0...360°
Wind speed sensor of the PRO-WEA series with
4...20 mA = 0...60 m/s
Wind speed sensor of the PRO-WEA series RF cup rotor and
4...20 mA = 0...60 m/s
Wind direction sensor of the ECONOMY series with
4...20 mA = 0...360°
Wind direction sensor of the METEOROLOGY series with potenti-
ometer (1000 Ω).
Wind direction sensor of the METEOROLOGY series
Output: 0...20 mA = 0...360°
Wind direction sensor of the METEOROLOGY series
Output: 0...20 mA = 0...360°
Wind direction sensor of the INDUSTRY series with
0...20 mA = 0...360°
Wind direction sensor of the INDUSTRY series with
4...20 mA = 0...360°
Wind speed sensor of the ECONOMY series
Output: 0...20 mA = 0...35 m/s
Wind speed sensor of the ECONOMY series
Output: 4...20 mA = 0...35 m/s
Wind speed sensor of the METEOROLOGY series
Output: 0...20 mA = 0...50 m/s
Wind speed sensor of the METEOROLOGY series
Output: 4...20 mA = 0...50 m/s
Wind speed sensor of the INDUSTRY series with
0...20 mA = 0...50 m/s
Wind speed sensor of the INDUSTRY series with
4...20 mA = 0...50 m/s
Level sensor for evaporation measurement with
0...5 V = 0...200 mm
Second Class – Global radiation sensor with mV output. (EMK [in
µV/(W/m²)] must be specified individually for each sensor.)
Radiation balance sensor with mV output at one input. Observe
special connection circuitry!
Net radiometer with mV output.
Second Class – Global radiation sensor with mV output. (EMK [in
µV/(W/m²)] must be specified individually for each sensor.)
First Class – Global radiation sensor with mV output. (EMK [in
µV/(W/m²)] must be specified individually for each sensor.)
Brightness sensor with 4...20 mA = 0...100 kLux