Maintenance

Maintenance
Frequency
Daily and at refill
Daily
Monthly

Cleaning the Reservoir

Only use water or solvents compatible with polycarbon-
ate to clean reservoir.
NOTICE
Most solvents will degrade the polycarbonate reser-
voir and cause it to fail.
16
Component
Zerk Fittings
G3 Pump Unit and Reservoir
External Wiring Harness

Recycling and Disposal

End of Product Life

At the end of the product's useful life, dismantle and
recycle it in a responsible manner.
Required Maintenance
Keep all fittings clean using a clean
dry cloth. Dirt and debris can dam-
age pump and lubrication system.
Keep pump unit and reservoir clean
using a clean dry cloth.
Verify external harnesses are secure.
Perform the Pressure Relief Procedure, page 12.
Drain and dispose of fluids according to applicable
regulations. Refer to the material manufacturer's
Safety Data Sheet.
Remove motors, circuit boards, LCDs (liquid crystal
displays), and other electronic components.
Recycle according to applicable regulations.
Do not dispose of electronic components with
household or commercial waste.
Deliver remaining product to a recycling facility.